Evidence map›Paper›PMID 31027505›Full record

ArticleBMC musculoskeletal disorders2019

Biomechanical comparison between solid and cannulated intramedullary devices for midshaft clavicle fixation.

Sheng-Hao Wang, Hsiu-Jen Lin, Hsain-Chung Shen, Ru-Yu Pan, Jui-Jung Yang

Open access · goldAbstract readComparative Study
In one paragraph

Article in BMC musculoskeletal disorders, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
0.6field-weighted citation impact, top 30% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed, 7 citations in OpenAlex.

  1. Article
  2. Article
  3. Observational
  4. The anterior head of deltoid in relation to anterior clavicle plating: how much are we releasing?OTA international : the open access journal of orthopaedic trauma · 2022
    Article
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 2 institutions in 1 country.

Sheng-Hao WangDepartment of Orthopaedics, Tri-Service General Hospital, National Defense Medical Center, No. 325, Cheng-Kung Road Section 2, Taipei, 114, Taiwan, Republic of China.
Hsiu-Jen LinDepartment of Mechanical Engineering, National Taipei University of Technology, Taipei, Taiwan.
Hsain-Chung ShenDepartment of Orthopaedics, Tri-Service General Hospital, National Defense Medical Center, No. 325, Cheng-Kung Road Section 2, Taipei, 114, Taiwan, Republic of China.
Ru-Yu PanDepartment of Orthopaedics, Tri-Service General Hospital, National Defense Medical Center, No. 325, Cheng-Kung Road Section 2, Taipei, 114, Taiwan, Republic of China.
Jui-Jung YangDepartment of Orthopaedics, Tri-Service General Hospital, National Defense Medical Center, No. 325, Cheng-Kung Road Section 2, Taipei, 114, Taiwan, Republic of China. tomshwang0628@gmail.com.ORCID http://orcid.org/0000-0001-9577-820X
Tri-Service General Hospital · TWNational Taipei University of Technology · TW

Funding

Research Foundation of Tri-Service General Hospital TSGH-C102-089
6 · The paper itself

Abstract

backgroundA method of closed reduction and internal fixation with cannulated screws was proposed as a surgical treatment of midshaft clavicle fractures. However, there are no mechanical studies about the cannulated screw used in the fixation of midshaft clavicle fracture. We conducted this study to compare the construct bending stiffness of a fixation midshaft clavicle fracture with a Knowles pin, cannulated screw and reconstruction plate. In addition, purchase lengths of both intramedullary devices were measured.

methodsAfter transverse osteotomy over the midpoint for fracture simulation, eighteen synthetic clavicles were assigned to 3 groups and fixed with reconstruction plate, Knowles pin or cannulated screw. Purchase length was defined as the engaged length of the intramedullary portion of the two intramedullary devices Stiffness, yield load and maximum load of the cantilever bending test were calculated of each tested synthetic bones.

resultsThe Knowles pin group had a significantly longer average intramedullary purchase length compared with that of the cannulated screw group. The construct stiffness in the reconstruction plate group (5.6 ± 0.9 N/mm) was higher than that of the intramedullary devices; the Knowles pin group (3.1 ± 0.6 N/mm) provided a greater construct stiffness than did the cannulated screw group (1.7 ± 0.4 N/mm) (p = 0.007). The cannulated screw group had the lowest yield and maximum load compared with the reconstruction plate and Knowles pin groups. Both the reconstruction plate and Knowles pin failed at the implant-bone interface. However, the cannulated screw group failed at the osteotomy site with broken implants.

conclusionThis study suggests that fixation of midshaft clavicle fractures with cannulated screws may lead to early failure due to inadequate mechanical strength. Ideal intramedullary clavicle devices should supply adequate intramedullary purchase lengths and mechanical strength.

Indexed as

Equipment FailureBiomechanical PhenomenaBone PlatesBone ScrewsCannulaClavicleFracture Fixation, IntramedullaryFractures, BoneHumansMaterials TestingCannulated screwIntramedullary deviceMidshaft clavicle fracture

Identifiers

PMID31027505
PMCPMC6485083
OpenAlexW2942923699

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.