Evidence map›Paper›PMID 31027302›Full record

Trial reportSensors (Basel, Switzerland)2019

Sock-Type Wearable Sensor for Estimating Lower Leg Muscle Activity Using Distal EMG Signals.

Takashi Isezaki, Hideki Kadone, Arinobu Niijima, Ryosuke Aoki, Tomoki Watanabe, Toshitaka Kimura, Kenji Suzuki

Open access · goldAbstract readClinical Trial
In one paragraph

Trial report in Sensors (Basel, Switzerland), 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed
1.8field-weighted citation impact, top 16% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed, 33 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Review
  5. Review
  6. Review
  7. Review
  8. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 2 institutions in 1 country.

Takashi IsezakiNTT Service Evolution Laboratories, Nippon Telegraph and Telephone Corporation, 1-1 Hikarinooka, Yokosuka, Kanagawa 239-0847, Japan. takashi.isezaki.xd@hco.ntt.co.jp.ORCID 0000-0002-4895-7333
Hideki KadoneCenter for Cybernics Research, University of Tsukuba, 1-1-1 Tennodai, Tsukuba, Ibaraki 305-8573, Japan. kadone@ai.iit.tsukuba.ac.jp.
Arinobu NiijimaNTT Plala Inc., TOC Ariake East Tower 14F, 3-5-7 Ariake, Koto-ku, Tokyo 135-0063, Japan. niijima@plala.co.jp.
Ryosuke AokiNTT Service Evolution Laboratories, Nippon Telegraph and Telephone Corporation, 1-1 Hikarinooka, Yokosuka, Kanagawa 239-0847, Japan. ryousuke.aoki.nz@hco.ntt.co.jp.
Tomoki WatanabeNTT Service Evolution Laboratories, Nippon Telegraph and Telephone Corporation, 1-1 Hikarinooka, Yokosuka, Kanagawa 239-0847, Japan. tomoki.watanabe.cd@hco.ntt.co.jp.
Toshitaka KimuraNTT Communication Science Laboratories, 3-1 Morinosato-Wakamiya, Atsugi, Kanagawa 243-0198, Japan. toshitaka.kimura.kd@hco.ntt.co.jp.
Kenji SuzukiFaculty of Engineering, Information and Systems, University of Tsukuba, 1-1-1 Tennodai, Tsukuba, Ibaraki 305-8573, Japan. kenji@ieee.org.ORCID 0000-0003-1736-5404
NTT (Japan) · JPUniversity of Tsukuba · JP

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Lower leg muscle activity contributes to body control; thus, monitoring lower leg muscle activity is beneficial to understand the body condition and prevent accidents such as falls. Amplitude features such as the mean absolute values of electromyography (EMG) are used widely for monitoring muscle activity. Garment-type EMG measurement systems use electrodes and they enable us to monitor muscle activity in daily life without any specific knowledge and the installation for electrode placement. However, garment-type measurement systems require a high compression area around the electrodes to prevent electrode displacement. This makes it difficult for users to wear such measurement systems. A less restraining wearable system, wherein the electrodes are placed around the ankle, is realized for target muscles widely distributed around the shank. The signals obtained from around the ankle are propagated biosignals from several muscles, and are referred to as

Indexed as

Wearable Electronic DevicesAdultElectromyographyHumansIsometric ContractionLegMaleMuscle, SkeletalSignal Processing, Computer-Assisteddistal EMG signalmuscle activity estimationwearable

Identifiers

PMID31027302
PMCPMC6515318
OpenAlexW2941953563

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked