Evidence map›Paper›PMID 31027206›Full record

ArticleMaterials (Basel, Switzerland)2019

In Vitro Effect of Drilling Speed on the Primary Stability of Narrow Diameter Implants with Varying Thread Designs Placed in Different Qualities of Simulated Bone.

Georgios E Romanos, Daniel J Bastardi, Rachel Moore, Apoorv Kakar, Yaro Herin, Rafael A Delgado-Ruiz

Abstract read
In one paragraph

Article in Materials (Basel, Switzerland), 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Georgios E RomanosDepartment of Periodontology, Laboratory for Periodontal-, Implant-, Phototherapy (LA-PIP), School of Dental Medicine, Stony Brook University, Stony Brook, New York, NY 11794, USA. georgios.romanos@stonybrookmedicine.edu.
Daniel J BastardiDepartment of Periodontology, Laboratory for Periodontal-, Implant-, Phototherapy (LA-PIP), School of Dental Medicine, Stony Brook University, Stony Brook, New York, NY 11794, USA. Daniel.Bastardi@stonybrook.edu.
Rachel MooreDepartment of Periodontology, Laboratory for Periodontal-, Implant-, Phototherapy (LA-PIP), School of Dental Medicine, Stony Brook University, Stony Brook, New York, NY 11794, USA. Rachel.moore@stonybrook.edu.
Apoorv KakarDepartment of Periodontology, Laboratory for Periodontal-, Implant-, Phototherapy (LA-PIP), School of Dental Medicine, Stony Brook University, Stony Brook, New York, NY 11794, USA. Apoorv.Kakar@stonybrook.edu.
Yaro HerinDepartment of Periodontology, Laboratory for Periodontal-, Implant-, Phototherapy (LA-PIP), School of Dental Medicine, Stony Brook University, Stony Brook, New York, NY 11794, USA. yaroslav.herin@stonybrook.edu.
Rafael A Delgado-RuizDepartment of Prosthodontics and Digital Technology, School of Dental Medicine, Stony Brook University, Stony Brook, New York, NY 11794, USA. rafael.delgado-ruiz@stonybrook.edu.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

It is hypothesized that there is no statistically significant impact of drilling speed (DS) on the primary stability (PS) of narrow-diameter implants (NDIs) with varying thread designs placed in dense and soft simulated bone. The aim of this in vitro study was to evaluate the impact of DS on the PS of NDIs with varying thread designs placed in dense and soft simulated bone. Two hundred and forty osteotomies for placement of various implant macro-designs were divided into three groups (80 implants per group): Group A (NobelActive, 3.0/11.5 mm); Group B (Astra OsseoSpeed-EV, 3.0/11 mm); and Group C (Eztetic-Zimmer, 3.1/11.5 mm) implants. These implants were placed in artificial dense and soft simulated bone using DSs of 800 and 2000 revolutions per minute (RPM). Resonance frequency analysis (RFA) and implant stability quotient (ISQ) were assessed. Group comparisons were performed using the one-way analysis of variance with Tukey's post hoc tests. Level of significance was set at P < 0.05. In groups A and B, there was no difference in the ISQ for NDIs inserted in dense bone at 800 and 2000 RPM. In Group C, ISQ was significantly higher for NDIs placed in dense bone at 800 PRM compared to 2000 RPM (P < 0.05). In Group A, ISQ values were significantly higher for NDIs inserted in soft bone at 2000 RPM as compared to those inserted at 800 RPM (P < 0.05). For NDIs, a lower drilling speed in dense artificial simulated bone and a higher drilling speed in soft artificial simulated bone is associated with high primary stability.

Indexed as

drilling speedimplant stability quotientnarrow diameter implantsprimary stability

Identifiers

PMID31027206
PMCPMC6515434

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.