Evidence map›Paper›PMID 31025811›Full record

ArticleOrthopaedic surgery2019

Correlation Between Reduction Quality of Femoral Neck Fracture and Femoral Head Necrosis Based on Biomechanics.

Ying Wang, Jian-Xiong Ma, Tao Yin, Zhe Han, Shuang-Shuang Cui, Zhi-Peng Liu, Xin-Long Ma

Open access · goldAbstract read
In one paragraph

Article in Orthopaedic surgery, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 64 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
64citing papers in PubMed, 1 pooled it
10.4field-weighted citation impact, top 1% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

64 citing papers in PubMed, 1 synthesis or guideline pooled it, 94 citations in OpenAlex.

  1. Pooled it
  2. Trial
  3. Trial
  4. Trial
  5. Trial
  6. Trial
  7. Early mechanical failure patterns after femoral neck fixation with the femoral neck system and dynamic hip screw.European journal of orthopaedic surgery & traumatology : orthopedie traumatologie · 2026
    Article
  8. Article
  9. Article
  10. Article
  11. Article
  12. Article
  13. Article
  14. Article
  15. Article
  16. Article
  17. Article
  18. Article
  19. Article
  20. Article

4 more citing papers are in PubMed but not listed here.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 2 institutions in 1 country.

Ying WangInstitute of Biomedical Engineering, Chinese Academy of Medical Sciences and Peking Union Medical College, Tianjin, China.
Jian-Xiong MaDigital Orthopaedic Laboratories of the Orthopaedic Institute, Tianjin Hospital, Tianjin, China.
Tao YinInstitute of Biomedical Engineering, Chinese Academy of Medical Sciences and Peking Union Medical College, Tianjin, China.
Zhe HanDigital Orthopaedic Laboratories of the Orthopaedic Institute, Tianjin Hospital, Tianjin, China.
Shuang-Shuang CuiDigital Orthopaedic Laboratories of the Orthopaedic Institute, Tianjin Hospital, Tianjin, China.
Zhi-Peng LiuInstitute of Biomedical Engineering, Chinese Academy of Medical Sciences and Peking Union Medical College, Tianjin, China.ORCID https://orcid.org/0000-0001-9793-6697
Xin-Long MaDigital Orthopaedic Laboratories of the Orthopaedic Institute, Tianjin Hospital, Tianjin, China.
Tianjin Hospital · CNChinese Academy of Medical Sciences & Peking Union Medical College · CN

Funding

National Natural Science Foundation of China 11772226National Natural Science Foundation of China 81572154Postdoctoral Science Foundation of China 2017M621087Tianjin Postdoctoral Innovation Project TJQYBSH2017017
6 · The paper itself

Abstract

objectiveTo investigate the biomechanical effects of reduction quality on patients after femoral neck fracture internal fixation.

methodsThe data of individual patients with femoral neck fractures were reviewed. Data for patients with simple unilateral femoral neck fractures whose reduction quality was evaluated as good by hip X-ray films after internal fixation were collected from January 2013 to January 2017. The CT data of the patients was used to reconstruct 3D models of the femur and the screw. The spatial displacement after the operation of femoral neck fracture was measured, which included the displacement of the deepest portion of the femoral head fovea, the displacement of the center of the femoral head, and the rotational angle. The cases were followed up by telephone consultation and clinical review to determine whether the osteonecrosis of the femoral head occurred. Follow-up time should be more than 18 months after surgery. The cases were grouped according to the results into an osteonecrosis of the femoral head group and a non-osteonecrosis of the femoral head group. Finally, the differences in postoperative spatial displacement between the two groups were compared and analyzed. In addition, a mechanical analysis of femoral force during gait was performed via finite element analysis.

resultsData for 241 patients with femoral neck fractures who were treated with closed reduction and internal fixation were collected. 3D measurement showed the average displacement value, including the center of the femoral head (5.90 ± 3.4 mm), the deepest portion of the femoral head fovea (9.32 ± 4.8 mm), and the rotational angle (16.1° ± 9.4°). After telephone consultation and clinical review, osteonecrosis of the femoral head was diagnosed in 28 (11.62%) of the patients. In the osteonecrosis of the femoral head (ONFH) group, the displacement of the deepest portion of the femoral head fovea was 10.92 ± 9.18 mm; the displacement was 8.86 ± 6.29 mm in the non-ONFH group. The displacement of the center of the femoral head in the ONFH group was 7.575 ± 5.69 mm and 5.31 ± 4.05 mm in non-ONFH group. The rotational angle was 20.11° ± 10.27° in the ONFH group and 14.19° ± 11.09° in the non-ONFH group. The statistical analysis showed that the postoperative spatial displacements, including the displacement of the deepest portion of the femoral head fovea, the displacement of the center of the femoral head, and the rotational angle between the two groups, had statistical differences. Finite element analysis showed that as the spatial displacement increased, the stress, the displacement, and the equivalent strain of the proximal femur also increased.

conclusionPoor reduction quality after femoral neck fracture is a risk factor for re-fracture and femoral head necrosis, and the measurement method of this study can be used to predict the occurrence of femoral head necrosis early after femoral neck fracture.

Indexed as

Fracture Fixation, InternalBiomechanical PhenomenaFemaleFemoral Neck FracturesFemur Head NecrosisFinite Element AnalysisHumansImaging, Three-DimensionalMaleMiddle AgedRadiographyStress, MechanicalFemoral head necrosisFemoral neck fractureFinite element analysisGaitReduction quality

Identifiers

PMID31025811
PMCPMC6594541
OpenAlexW2941155094

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.