SynthesisThe Cochrane database of systematic reviews2019
Prostate MRI, with or without MRI-targeted biopsy, and systematic biopsy for detecting prostate cancer.
Synthesis in The Cochrane database of systematic reviews, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to 8 registered trials, which are not on this map. Cited by 356 papers, 6 of them syntheses that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
A Randomized Controlled Trial Comparing Magnetic Resonance Imaging (MRI)-Targeted Biopsy and Extended Transperineal Systematic Biopsy for Detection of Clinically Significant Prostate Cancer: the SMART Trial
Prospective Randomized Controlled Study: Free-Hand Transperineal vs. Transrectal Systematic and Image Fusion Targeted Biopsies Under Local Anesthesia Comparing Rate of Significant Cancer Detection and Complication Rates
Utility of Biparametric MRI (Magnetic Resonance Imaging) as a Screening Tool for Prostate Cancer in a High-Risk Cohort
The Performance of MRI Prostate in Men With Different Prostate Health Index (Phi) Values: Can we Save Some MRI Scans?
A Randomised Controlled Trial Comparing MRI-Ultrasound Fusion and Cognitive-guided Biopsy for the Detection of Clinically Significant Prostate Cancer: the PROFUSION Trial
The Role of 18F-PSMA PET in Prostate Cancer Diagnosis in Equivocal MRI: a Multi-center Randomised Controlled Trial
A Multicenter Study of a Deep Learning Model Based on Spatial Registration of Multimodal Imaging and Digital Pathology for Predicting Clinically Significant Prostate Cancer
Investigation of an Intelligent Centre-adaptive Multi-modal Fusion Framework (Cad- MMFF) to Overcome Unnecessary Prostate Biopsies and Optimize MRI Utilization: a Hybrid Retrospective-prospective Study
Who cites it
356 citing papers in PubMed, 6 syntheses or guidelines pooled it.
- Refining biopsy strategies stratified by PI-RADS score in men: a systematic review and network meta-analysis.Nature communications · 2026Pooled it
- Clinical impact of MRI-based risk calculators for prostate cancer diagnosis: a systematic review and meta-analysis.Prostate cancer and prostatic diseases · 2026Pooled it
- MRI software and cognitive fusion biopsies in people with suspected prostate cancer: a systematic review, network meta-analysis and cost-effectiveness analysis.Health technology assessment (Winchester, England) · 2024Pooled it
- Diagnostic Performance of Prostate-specific Antigen Density for Detecting Clinically Significant Prostate Cancer in the Era of Magnetic Resonance Imaging: A Systematic Review and Meta-analysis.European urology oncology · 2024Pooled it
- [Prostate cancer-multiparametric MRI and alternative approaches in intervention and therapy planning].Urologie (Heidelberg, Germany) · 2023Pooled it
- Early Detection of Prostate Cancer: AUA/SUO Guideline Part II: Considerations for a Prostate Biopsy.The Journal of urology · 2023Guideline
- Safety and patient-reported outcomes of multimodal PSMA PET/MRI-guided prostate biopsy: results from the prospective multicenter DEPROMP trial.World journal of urology · 2026Trial
- Prostate cancer screening: weighing the benefits and harms.Nature reviews. Urology · 2026Article
- Prospective evaluation of the PRIMARY score using [European journal of nuclear medicine and molecular imaging · 2026Article
- Are template prostate biopsies still required in patients with high-risk PI-RADS lesions? A retrospective study of 470 patients.BJUI compass · 2026Article
- AI-Assisted Prostate Cancer Diagnosis Using Biparametric MRI and PI-RADS v2.1: Performance Comparison Between Novice-Level and Experienced Readers.Journal of magnetic resonance imaging : JMRI · 2026Article
- An Assessment of PI-RADS v2.1: Inter-Reader Agreement, Diagnostic Accuracy, and the Added Value of PSA Density in Prostate Cancer Prediction.Diagnostics (Basel, Switzerland) · 2026Article
- Incremental Value of PI-RADS v2.1 for Adverse Pathology at Radical Prostatectomy: A Retrospective 1.5-T MRI Cohort.Current oncology (Toronto, Ont.) · 2026Article
- Prostate MRI reporting and its impact on clinical decision-making: the urologists' perspective.Abdominal radiology (New York) · 2026Review
- Article
- Vitamin D and adverse pathologic features in patients undergoing radical prostatectomy in the contemporary magnetic resonance imaging-guided management era.BJUI compass · 2026Article
- Adoption of MRI-guided Prostate Cancer Diagnostics and Surgical Outcomes: A Prospective Multicenter Registry Study.European urology open science · 2026Article
- Incorporating Lower Urinary Tract Symptoms to Predict the Risk of Positive Prostate Magnetic Resonance Imaging.European urology open science · 2026Article
- Ongoing and completed clinical trials on prostate cancer screening using MRI.European radiology · 2026Review
- Towards implementation of precision medicine biomarkers in early detection and prognostication of prostate cancer.Cancer metastasis reviews · 2026Review
296 more citing papers are in PubMed but not listed here.
Corrections and comments
- Commented on by
- Commented on by
Authors and funding
7 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundMultiparametric magnetic resonance imaging (MRI), with or without MRI-targeted biopsy, is an alternative test to systematic transrectal ultrasonography-guided biopsy in men suspected of having prostate cancer. At present, evidence on which test to use is insufficient to inform detailed evidence-based decision-making.
objectivesTo determine the diagnostic accuracy of the index tests MRI only, MRI-targeted biopsy, the MRI pathway (MRI with or without MRI-targeted biopsy) and systematic biopsy as compared to template-guided biopsy as the reference standard in detecting clinically significant prostate cancer as the target condition, defined as International Society of Urological Pathology (ISUP) grade 2 or higher. Secondary target conditions were the detection of grade 1 and grade 3 or higher-grade prostate cancer, and a potential change in the number of biopsy procedures. SEARCH
methodsWe performed a comprehensive systematic literature search up to 31 July 2018. We searched CENTRAL, MEDLINE, Embase, eight other databases and one trials register. SELECTION CRITERIA: We considered for inclusion any cross-sectional study if it investigated one or more index tests verified by the reference standard, or if it investigated the agreement between the MRI pathway and systematic biopsy, both performed in the same men. We included only studies on men who were biopsy naïve or who previously had a negative biopsy (or a mix of both). Studies involving MRI had to report on both MRI-positive and MRI-negative men. All studies had to report on the primary target condition. DATA COLLECTION AND ANALYSIS: Two reviewers independently extracted data and assessed the risk of bias using the QUADAS-2 tool. To estimate test accuracy, we calculated sensitivity and specificity using the bivariate model. To estimate agreement between the MRI pathway and systematic biopsy, we synthesised detection ratios by performing random-effects meta-analyses. To estimate the proportions of participants with prostate cancer detected by only one of the index tests, we used random-effects multinomial or binary logistic regression models. For the main comparisions, we assessed the certainty of evidence using GRADE. MAIN
resultsThe test accuracy analyses included 18 studies overall.MRI compared to template-guided biopsy: Based on a pooled sensitivity of 0.91 (95% confidence interval (CI): 0.83 to 0.95; 12 studies; low certainty of evidence) and a pooled specificity of 0.37 (95% CI: 0.29 to 0.46; 12 studies; low certainty of evidence) using a baseline prevalence of 30%, MRI may result in 273 (95% CI: 249 to 285) true positives, 441 false positives (95% CI: 378 to 497), 259 true negatives (95% CI: 203 to 322) and 27 (95% CI: 15 to 51) false negatives per 1000 men. We downgraded the certainty of evidence for study limitations and inconsistency.MRI-targeted biopsy compared to template-guided biopsy: Based on a pooled sensitivity of 0.80 (95% CI: 0.69 to 0.87; 8 studies; low certainty of evidence) and a pooled specificity of 0.94 (95% CI: 0.90 to 0.97; 8 studies; low certainty of evidence) using a baseline prevalence of 30%, MRI-targeted biopsy may result in 240 (95% CI: 207 to 261) true positives, 42 (95% CI: 21 to 70) false positives, 658 (95% CI: 630 to 679) true negatives and 60 (95% CI: 39 to 93) false negatives per 1000 men. We downgraded the certainty of evidence for study limitations and inconsistency.The MRI pathway compared to template-guided biopsy: Based on a pooled sensitivity of 0.72 (95% CI: 0.60 to 0.82; 8 studies; low certainty of evidence) and a pooled specificity of 0.96 (95% CI: 0.94 to 0.98; 8 studies; low certainty of evidence) using a baseline prevalence of 30%, the MRI pathway may result in 216 (95% CI: 180 to 246) true positives, 28 (95% CI: 14 to 42) false positives, 672 (95% CI: 658 to 686) true negatives and 84 (95% CI: 54 to 120) false negatives per 1000 men. We downgraded the certainty of evidence for study limitations, inconsistency and imprecision.Systemic biopsy compared to template-guided biopsy: Based on a pooled sensitivity of 0.63 (95% CI: 0.19 to 0.93; 4 studies; low certainty of evidence) and a pooled specificity of 1.00 (95% CI: 0.91 to 1.00; 4 studies; low certainty of evidence) using a baseline prevalence of 30%, systematic biopsy may result in 189 (95% CI: 57 to 279) true positives, 0 (95% CI: 0 to 63) false positives, 700 (95% CI: 637 to 700) true negatives and 111 (95% CI: 21 to 243) false negatives per 1000 men. We downgraded the certainty of evidence for study limitations and inconsistency.Agreement analyses: In a mixed population of both biopsy-naïve and prior-negative biopsy men comparing the MRI pathway to systematic biopsy, we found a pooled detection ratio of 1.12 (95% CI: 1.02 to 1.23; 25 studies). We found pooled detection ratios of 1.44 (95% CI 1.19 to 1.75; 10 studies) in prior-negative biopsy men and 1.05 (95% CI: 0.95 to 1.16; 20 studies) in biopsy-naïve men. AUTHORS'
conclusionsAmong the diagnostic strategies considered, the MRI pathway has the most favourable diagnostic accuracy in clinically significant prostate cancer detection. Compared to systematic biopsy, it increases the number of significant cancer detected while reducing the number of insignificant cancer diagnosed. The certainty in our findings was reduced by study limitations, specifically issues surrounding selection bias, as well as inconsistency. Based on these findings, further improvement of prostate cancer diagnostic pathways should be pursued.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.