Evidence map›Paper›PMID 31022287›Full record

ArticlePloS one2019

Highly sensitive detection of influenza virus with SERS aptasensor.

Vladimir I Kukushkin, Nikita M Ivanov, Anastasia A Novoseltseva, Alexandra S Gambaryan, Igor V Yaminsky, Alexey M Kopylov, Elena G Zavyalova

Open access · goldAbstract read
In one paragraph

Article in PloS one, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 49 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
49citing papers in PubMed, 1 pooled it
7.2field-weighted citation impact, top 2% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

49 citing papers in PubMed, 1 synthesis or guideline pooled it, 118 citations in OpenAlex.

  1. Aptamers used for biosensors and targeted therapy.Biomedicine & pharmacotherapy = Biomedecine & pharmacotherapie · 2020
    Pooled it
  2. Review
  3. Review
  4. Review
  5. Review
  6. Article
  7. Article
  8. Review
  9. Diverse applications and development of aptamer detection technology.Analytical sciences : the international journal of the Japan Society for Analytical Chemistry · 2023
    Review
  10. Article
  11. Review
  12. Review
  13. Review
  14. Review
  15. Aptamer-based biosensors for virus protein detection.Trends in analytical chemistry : TRAC · 2022
    Review
  16. Article
  17. Aptamers: A prospective tool for infectious diseases diagnosis.Journal of clinical laboratory analysis · 2022
    Review
  18. Article
  19. Review
  20. Aptamers for Viral Detection and Inhibition.ACS infectious diseases · 2022
    Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 3 institutions in 1 country.

Vladimir I KukushkinInstitute of Solid State Physics RAS, Chernogolovka, Moscow district, Russian Federation.
Nikita M IvanovChemistry Department, Lomonosov Moscow State University, Moscow, Russian Federation.
Anastasia A NovoseltsevaChemistry Department, Lomonosov Moscow State University, Moscow, Russian Federation.
Alexandra S GambaryanChumakov Federal Scientific Center for Research and Development of Immune and Biological Products RAS, Moscow, Russian Federation.
Igor V YaminskyChemistry Department, Lomonosov Moscow State University, Moscow, Russian Federation.ORCID 0000-0001-8731-3947
Alexey M KopylovChemistry Department, Lomonosov Moscow State University, Moscow, Russian Federation.
Elena G ZavyalovaChemistry Department, Lomonosov Moscow State University, Moscow, Russian Federation.ORCID 0000-0001-5260-1973
Lomonosov Moscow State University · RUOsipyan Institute of Solid State Physics RAS · RUState Research Center of the Russian Federation · RU

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Highly sensitive and rapid technology of surface enhanced Raman scattering (SERS) was applied to create aptasensors for influenza virus detection. SERS achieves 106-109 times signal amplification, yielding excellent sensitivity, whereas aptamers to hemagglutinin provide a specific recognition of the influenza virus. Aptamer RHA0385 was demonstrated to have essentially broad strain-specificity toward both recombinant hemagglutinins and the whole viruses. To achieve high sensitivity, a sandwich of primary aptamers, influenza virus and secondary aptamers was assembled. Primary aptamers were attached to metal particles of a SERS substrate, and influenza viruses were captured and bound with secondary aptamers labelled with Raman-active molecules. The signal was affected by the concentration of both primary and secondary aptamers. The limit of detection was as low as 1 · 10-4 hemagglutination units per probe as tested for the H3N2 virus (A/England/42/72). Aptamer-based sensors provided recognition of various influenza viral strains, including H1, H3, and H5 hemagglutinin subtypes. Therefore, the aptasensors could be applied for fast and low-cost strain-independent determination of influenza viruses.

Indexed as

Aptamers, NucleotideBiosensing TechniquesInfluenza A Virus, H3N2 SubtypeSpectrum Analysis, RamanSurface Plasmon ResonanceAptamers, Nucleotide

Identifiers

PMID31022287
PMCPMC6483365
OpenAlexW2941178846

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.