ArticlePloS one2019

A geometric calibration method for the digital chest tomosynthesis with dual-axis scanning geometry.

Chia-Hao Chang, Yu-Ching Ni, Syuan-Ya Huang, Ho-Hui Hsieh, Sheng-Pin Tseng, Fan-Pin Tseng

Abstract read
In one paragraph

Article in PloS one, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. [Extraction of respiratory signals from chest tomosynthesis].Nan fang yi ke da xue xue bao = Journal of Southern Medical University · 2021
    Article
  7. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Chia-Hao ChangHealth Physics Division, Institute of Nuclear Energy Research, Atomic Energy Council, Taoyuan, Taiwan.ORCID 0000-0002-4862-9436
Yu-Ching NiHealth Physics Division, Institute of Nuclear Energy Research, Atomic Energy Council, Taoyuan, Taiwan.
Syuan-Ya HuangHealth Physics Division, Institute of Nuclear Energy Research, Atomic Energy Council, Taoyuan, Taiwan.
Ho-Hui HsiehHealth Physics Division, Institute of Nuclear Energy Research, Atomic Energy Council, Taoyuan, Taiwan.
Sheng-Pin TsengHealth Physics Division, Institute of Nuclear Energy Research, Atomic Energy Council, Taoyuan, Taiwan.
Fan-Pin TsengHealth Physics Division, Institute of Nuclear Energy Research, Atomic Energy Council, Taoyuan, Taiwan.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The aim of this study was to develop a geometric calibration method capable of eliminating the reconstruction artifacts of geometric misalignments in a tomosynthesis prototype with dual-axis scanning geometry. The potential scenarios of geometric misalignments were demonstrated, and their effects on reconstructed images were also evaluated. This method was a phantom-based approach with iterative optimization, and the calibration phantom was designed for specific tomosynthesis scanning geometry. The phantom was used to calculate a set of geometric parameters from each projection, and these parameters were then used to evaluate the geometric misalignments of the dual-axis scanning-geometry prototype. The simulated results revealed that the extracted geometric parameters were similar to the input values and that the artifacts of reconstructed images were minimized due to geometric calibration. Additionally, experimental chest phantom imaging results also indicated that the artifacts of the reconstructed images were suppressed and that object structures were preserved through calibration. And the quantitative analysis result also indicated that the MTF can be further improved with the geometric calibration. All the simulated and experimental results demonstrated that this method is effective for tomosynthesis with dual-axis scanning geometry. Furthermore, this geometric calibration method can also be applied to other tomography imaging systems to reduce geometric misalignments and be used for different geometric calibration phantom configurations.

Indexed as

CalibrationComputer SimulationHumansImage Processing, Computer-AssistedPhantoms, ImagingThoraxX-Rays

Identifiers

PMID31022255
PMCPMC6483259

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.