Article in Journal of clinical medicine, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
- Multimodality Cardiovascular Imaging for Totally Video-Guided Thorascopic Cardiac Surgery.Reviews in cardiovascular medicine · 2024Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Although intravenous administration of contrast media may trigger a variety of adverse reactions, sedated patients undergoing computed tomography (CT) scanning usually are not able to report their symptoms, which may delay detection of adverse reactions. Furthermore, changes in vital signs cannot be typically measured during mobile CT scanning, which worsens the situation. We aimed to characterize contrast-related hemodynamic changes that occur during mobile CT scanning and predict sudden hypotension based on subtle but robust changes in the electrocardiogram (ECG). We analyzed the digitized hemodynamic data of 20 consecutive patients who underwent clipping of a cerebral artery aneurysm and contrast-enhanced CT scanning following the surgical procedure. Hemodynamic variables, including ECG findings, invasive blood pressure (BP), pulse oximetry results, capnography findings, cardiac output, and systemic vascular resistance, were monitored simultaneously. We measured morphological changes in ECG-derived parameters, including the R-R interval, ST height, and QRS R-amplitude, on a beat-to-beat basis, and evaluated the correlation between those parameters and hemodynamic changes. After the radiocontrast injection, systolic BP decreased by a median 53 mmHg from baseline and spontaneously recovered after 63 ± 19 s. An increase in QRS R-amplitude (median 0.43 mV) occurred 25 ± 10 s before hypotension developed. The receiver operating characteristic curve showed that a 16% increase in QRS R-amplitude can predict a decrease in systolic BP of >25% (area under the curve 0.852). Increased cardiac output (median delta 2.7 L/min from baseline) and decreased systemic vascular resistance (median delta 857 dyn·s/cm