ArticlePhysics in medicine and biology2019
Compton PET: a layered structure PET detector with high performance.
Article in Physics in medicine and biology, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 11 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
11 citing papers in PubMed.
- Recent advances in radionuclide medical imaging techniques.Frontiers in medicine · 2025Review
- Detectors in positron emission tomography.Zeitschrift fur medizinische Physik · 2023Review
- Timing, Energy, and 3-D Spatial Resolution of the BING PET Detector Module.IEEE transactions on radiation and plasma medical sciences · 2023Article
- Self-Collimating SPECT With Multi-Layer Interspaced Mosaic Detectors.IEEE transactions on medical imaging · 2021Article
- Optical Simulation and Experimental Assessment with Time-Walk Correction of TOF-PET Detectors with Multi-Ended Readouts.Sensors (Basel, Switzerland) · 2021Article
- Tomographic imaging with Compton PET modules: ideal case and first implementation.Journal of instrumentation : an IOP and SISSA journal · 2021Article
- Evaluation of the PETsys TOFPET2 ASIC in multi-channel coincidence experiments.EJNMMI physics · 2021Article
- Sub-2 mm depth of interaction localization in PET detectors with prismatoid light guide arrays and single-ended readout using convolutional neural networks.Medical physics · 2021Article
- A digital phoswich detector using time-over-threshold for depth of interaction in PET.Physics in medicine and biology · 2020Article
- Small animal PET: a review of what we have done and where we are going.Physics in medicine and biology · 2020Review
- Prismatoid light guide array for enhanced gamma ray localization in PET: a Monte Carlo simulation study of scintillation photon transport.Physics in medicine and biology · 2020Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
3 authors.
Funding
Abstract
In most high-resolution PET detector designs, there is an inherent trade-off between spatial resolution and detector efficiency. We have developed and tested a new geometry for the detector module which avoids this trade-off. The module uses a layered structure, in which four crystal slabs are stacked in the depth direction and optically separated by enhanced specular reflector (ESR) film. The scintillation light within each layer is measured by 16 SiPMs located on the four sides of the crystal. Analog signals from all SiPMs (4 × 16) on the four sides of the crystal are digitized individually using a 64-channel TOFPET-2 module. The four-sided readout method reduces the problem of light trapping resulting from total internal reflection when reading out the end(s) of traditional scintillation crystal arrays, thus increasing the light collection efficiency. In this work, we demonstrate the readout of a complete layered detector with 4 layers. The high light collection efficiency results in a FWHM energy resolution of 10.3%, and a FWHM timing resolution of 348 ps. The distribution of scintillation light detected by the SiPMs was used to decode the interaction position of each gamma ray using a trained neural network. A FWHM spatial resolution of 1.1 ± 0.1 mm was achieved. This design allows the detection efficiency of the module to be increased by adding additional crystal slabs along the depth direction. Since the position, energy, and timing are measured for each layer independently, increasing the system sensitivity by adding more layers will not affect the spatial/energy/timing resolution. Furthermore, the layered structure allows partial recovery of position information for events that undergo Compton scatter within the detector.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.