Evidence map›Paper›PMID 31011693›Full record

ArticleIEEE transactions on radiation and plasma medical sciences2018

Simulations of a Multi-Pinhole SPECT Collimator for Clinical Dopamine Transporter (DAT) Imaging.

Arda Könik, Jan De Beenhouwer, Joyeeta M Mukherjee, Kesava Kalluri, Soumyanil Banerjee, Navid Zeraatkar, Timothy Fromme, Michael A King

Abstract read
In one paragraph

Article in IEEE transactions on radiation and plasma medical sciences, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 10 papers.

0numbers the graph read from it
0cells of the map it votes in
10citing papers in PubMed
2.2field-weighted citation impact, top 12% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

10 citing papers in PubMed, 19 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
  10. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 4 institutions in 2 countries.

Arda KönikDepartment of Radiology, UMass Medical School, Worcester, MA, USA.
Jan De BeenhouwerUniv. of Antwerp,imec-Vision Lab, Antwerp, Belgium.
Joyeeta M MukherjeeThe MathWorks, Inc., Natick, MA, USA.
Kesava KalluriDepartment of Radiology, UMass Medical School, Worcester, MA, USA.
Soumyanil BanerjeeDepartment of Radiology, UMass Medical School, Worcester, MA, USA.
Navid ZeraatkarDepartment of Radiology, UMass Medical School, Worcester, MA, USA.
Timothy FrommeWorcester Polytechnic University, Worcester,MA, USA.
Michael A KingDepartment of Radiology, UMass Medical School, Worcester, MA, USA.
University of Massachusetts Chan Medical School · USMathWorks (United States) · USUniversity of Antwerp · BEWorcester Polytechnic Institute · US

Funding

Combined Multi-Pinhole and Fan-Beam Brain SPECTR01EB022092 · NIBIB · UNIV OF MASSACHUSETTS MED SCH WORCESTER · PI KING, MICHAEL A · 2016 to 2019
$1.6M
NIBIB NIH HHS R01 EB022092
6 · The paper itself

Abstract

SPECT imaging of the dopamine transporter (DAT) is used for diagnosis and monitoring progression of Parkinson's Disease (PD), and differentiation of PD from other neurological disorders. The diagnosis is based on the DAT binding in the caudate and putamen structures in the striatum. We previously proposed a relatively inexpensive method to improve the detection and quantification of these structures for dual-head SPECT by replacing one of the fan-beam collimators with a specially designed multi-pinhole (MPH) collimator. In this work, we developed a realistic model of the proposed MPH system using the GATE simulation package and verified the geometry with an analytic simulator. Point source projections from these simulations closely matched confirming the accuracy of the pinhole geometries. The reconstruction of a hot-rod phantom showed that 4.8 mm resolution is achievable. The reconstructions of the XCAT brain phantom showed clear separation of the putamen and caudate, which is expected to improve the quantification of DAT imaging and PD diagnosis. Using this GATE model, point spread functions modeling physical factors will be generated for use in reconstruction. Also, further improvements in geometry are being investigated to increase the sensitivity of this base system while maintaining a target spatial resolution of 4.5-5 mm.

Indexed as

brainmulti-pinholesimulationSPECT

Identifiers

PMID31011693
PMCPMC6474676
OpenAlexW2801999984

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.