Evidence map›Paper›PMID 31010593›Full record

ArticleJournal of biomechanics2019

Layer-specific arterial micromechanics and microstructure: Influences of age, anatomical location, and processing technique.

Michael Rafuse, Xin Xu, Kurt Stenmark, Corey P Neu, Xiaobo Yin, Wei Tan

Open access · greenAbstract read
In one paragraph

Article in Journal of biomechanics, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 13 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
13citing papers in PubMed, 1 pooled it
0.9field-weighted citation impact, top 28% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

13 citing papers in PubMed, 1 synthesis or guideline pooled it, 18 citations in OpenAlex.

  1. Pooled it
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
  10. Review
  11. Article
  12. Article
  13. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 2 institutions in 1 country.

Michael RafuseDepartment of Mechanical Engineering, University of Colorado Boulder, Boulder, CO 80309, USA.
Xin XuDepartment of Mechanical Engineering, University of Colorado Boulder, Boulder, CO 80309, USA.
Kurt StenmarkCardiovascular Pulmonary Research Laboratories, University of Colorado Anschutz Medical Campus, Aurora, CO 80045, USA.
Corey P NeuDepartment of Mechanical Engineering, University of Colorado Boulder, Boulder, CO 80309, USA.
Xiaobo YinDepartment of Mechanical Engineering, University of Colorado Boulder, Boulder, CO 80309, USA.
Wei TanDepartment of Mechanical Engineering, University of Colorado Boulder, Boulder, CO 80309, USA. Electronic address: wtan@colorado.edu.
University of Colorado Boulder · USUniversity of Colorado Anschutz Medical Campus · US

Funding

Synthetic Mesenchymal Stem Cell Niches for Vascular TherapyR01HL119371 · NHLBI · UNIVERSITY OF COLORADO · PI TAN, WEI · 2013 to 2023
$5.0M
NHLBI NIH HHS R01 HL119371
6 · The paper itself

Abstract

The importance of matrix micromechanics is increasingly recognized in cardiovascular research due to the intimate role they play in local vascular cell physiology. However, variations in micromechanics among arterial layers (i.e. intima, media, adventitia), as well as dependency on local matrix composition and/or structure, anatomical location or developmental stage remain largely unknown. This study determined layer-specific stiffness in elastic arteries, including the main pulmonary artery, ascending aorta, and carotid artery using atomic force indentation. To compare stiffness with age and frozen processing techniques, neonatal and adult pulmonary arteries were tested, while fresh (vibratomed) and frozen (cryotomed) tissues were tested from the adult aorta. Results revealed that the mean compressive modulus varied among the intima, sub-luminal media, inner-middle media, and adventitia layers in the range of 1-10 kPa for adult arteries. Adult samples, when compared to neonatal pulmonary arteries, exhibited increased stiffness in all layers except adventitia. Compared to freshly isolated samples, frozen preparation yielded small stiffness increases in each layer to varied degrees, thus inaccurately representing physiological stiffness. To interpret micromechanics measurements, composition and structure analyses of structural matrix proteins were conducted with histology and multiphoton imaging modalities including second harmonic generation and two-photon fluorescence. Composition analysis of matrix protein area density demonstrated that decrease in the elastin-to-collagen and/or glycosaminoglycan-to-collagen ratios corresponded to stiffness increases in identical layers among different types of arteries. However, composition analysis was insufficient to interpret stiffness variations between layers which had dissimilar microstructure. Detailed microstructure analyses may contribute to more complete understanding of arterial micromechanics.

Indexed as

AdventitiaAgingAnimalsArteriesCattleCollagenElasticityElastinGlycosaminoglycansPressureTunica IntimaCollagenElastinGlycosaminoglycansAtomic force microscopyCollagenElastinGlycosaminoglycansMultiphoton microscopy

Identifiers

PMID31010593
PMCPMC6499687
OpenAlexW2927490428

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.