ArticleMaterials (Basel, Switzerland)2019
Microgrooves and Microrugosities in Titanium Implant Surfaces: An In Vitro and In Vivo Evaluation.
Article in Materials (Basel, Switzerland), 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 15 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
15 citing papers in PubMed, 22 citations in OpenAlex.
- Evaluation of surface roughness of titanium implants on human fibroblast cells.Scientific reports · 2026Article
- On the Use of Nanoparticles in Dental Implants.Materials (Basel, Switzerland) · 2024Review
- Conometric Connection for Implant-Supported Crowns: A Prospective Clinical Cohort Study.Journal of clinical medicine · 2023Article
- Endosseous Dental Implant Materials and Clinical Outcomes of Different Alloys: A Systematic Review.Materials (Basel, Switzerland) · 2022Review
- Titanium Coated with Graphene and Niobium Pentoxide for Biomaterial Applications.International journal of biomaterials · 2022Article
- Professional Mechanical Tooth Cleaning Method for Dental Implant Surface by Agar Particle Blasting.Materials (Basel, Switzerland) · 2021Article
- Clinical Evaluation of Dental Implants with a Double Acid-Etched Surface Treatment: A Cohort Observational Study with Up to 10-Year Follow-Up.Materials (Basel, Switzerland) · 2021Article
- Osteosphere Model to Evaluate Cell-Surface Interactions of Implantable Biomaterials.Materials (Basel, Switzerland) · 2021Article
- Effect of Plasma Treatment on Titanium Surface on the Tissue Surrounding Implant Material.International journal of molecular sciences · 2021Article
- Dental Pulp Stem Cells on Implant Surface: An In Vitro Study.BioMed research international · 2021Article
- Effects of Surface Modification on Adsorption Behavior of Cell and Protein on Titanium Surface by Using Quartz Crystal Microbalance System.Materials (Basel, Switzerland) · 2020Article
- Laser-Based Ablation of Titanium-Graphite Composite for Dental Application.Materials (Basel, Switzerland) · 2020Article
- Long-Term Clinical Outcomes of Treatment with Dental Implants with Acid Etched Surface.Materials (Basel, Switzerland) · 2020Article
- Article
- Sandblasted and Acid Etched Titanium Dental Implant Surfaces Systematic Review and Confocal Microscopy Evaluation.Materials (Basel, Switzerland) · 2019Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
9 authors at 6 institutions in 4 countries.
Funding
No grant is acknowledged in the PubMed record.
Abstract
The physical characteristics of an implant surface can determine and/or facilitate osseointegration processes. In this sense, a new implant surface with microgrooves associated with plus double acid treatment to generate roughness was evaluated and compared in vitro and in vivo with a non-treated (smooth) and double acid surface treatment. Thirty disks and thirty-six conical implants manufactured from commercially pure titanium (grade IV) were prepared for this study. Three groups were determined, as described below: Group 1 (G1), where the samples were only machined; group 2 (G2), where the samples were machined and had their surface treated to generate roughness; and test group 3 (G3), where the samples were machined with microgrooves and the surface was treated to generate the roughness. For the in vitro analysis, the samples were submitted to scanning microscopy (SEM), surface profilometry, the atomic force microscope (MFA) and the surface energy test. For the in vivo analyses, thirty-six implants were placed in the tibia of 9 New Zealand rabbits in a randomized manner, after histological and histomorphometric analysis, to determine the level of contact between the bone and implant (BIC%) and the bone area fraction occupancy (BAFO%) inside of the threads. The data collected were statistically analyzed between groups (
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.