ReviewEuropean stroke journal2017
Intra-arterial mechanical thrombectomy stent retrievers and aspiration devices in the treatment of acute ischaemic stroke: A systematic review and meta-analysis with trial sequential analysis.
Review in European stroke journal, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 11 papers, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
11 citing papers in PubMed, 1 synthesis or guideline pooled it, 22 citations in OpenAlex.
- Meta-Analysis of the Effectiveness and Safety of Intravenous Thrombolysis in Patients with Acute Cerebral Infarction.Computational and mathematical methods in medicine · 2021Pooled it
- Radially adjustable stent retriever for mechanical thrombectomy in acute ischemic stroke: Improved first-pass effect with rapid-inflation deflation technique.Interventional neuroradiology : journal of peritherapeutic neuroradiology, surgical procedures and related neurosciences · 2026Article
- Comparative verification of control methodology for robotic interventional neuroradiology procedures.International journal of computer assisted radiology and surgery · 2023Article
- National implementation of reperfusion for acute ischaemic stroke in England: How should services be configured? A modelling study.European stroke journal · 2022Article
- The cost of providing mechanical thrombectomy in the UK NHS: a micro-costing study.Clinical medicine (London, England) · 2020Article
- In vitro testing of a funnel-shaped tip catheter model to decrease clot migration during mechanical thrombectomy.Scientific reports · 2020Article
- The Minimal Clinically Important Difference for Achievement of Substantial Reperfusion With Endovascular Thrombectomy Devices in Acute Ischemic Stroke Treatment.Frontiers in neurology · 2020Article
- Safety and Efficacy of Mechanical Thrombectomy Using Tigertriever as a Rescue Device After Failed Aspiration-Single Center Experience.Frontiers in neurology · 2020Article
- Estimating the effectiveness and cost-effectiveness of establishing additional endovascular Thrombectomy stroke Centres in England: a discrete event simulation.BMC health services research · 2019Article
- Maximising access to thrombectomy services for stroke in England: A modelling study.European stroke journal · 2019Article
- A Delphi study and ranking exercise to support commissioning services: future delivery of Thrombectomy services in England.BMC health services research · 2018Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
11 authors at 4 institutions in 1 country.
Funding
Abstract
purposeIntra-arterial mechanical thrombectomy combined with appropriate patient selection (image-based selection of acute ischaemic stroke patients with large artery occlusion) yields improved clinical outcomes. We conducted a systematic review and meta-analysis, with trial sequential analysis to understand the benefits, risks and impact of new trials reporting in 2016 on the magnitude/certainty of the estimates for clinical effectiveness and safety of mechanical thrombectomy.
methodRandom effects' models were conducted of randomised clinical trials comparing mechanical thrombectomy (stent retriever or aspiration devices) with/without adjuvant intravenous thrombolysis with intravenous thrombolysis and other forms of best medical/supportive care in the treatment of acute ischaemic stroke. Study inclusion and risk of bias were assessed independently by two reviewers. Functional independence (modified Rankin Scale 0-2) and mortality at 90 days, including symptomatic intracranial haemorrhage rate were extracted. Trial sequential analysis established the strength of the evidence derived from the meta-analyses.
findingsEight trials of mechanical thrombectomy with a total sample size of 1841 (916 patients treated with mechanical thrombectomy and 925 treated without mechanical thrombectomy) fulfilled review inclusion criteria. The three most recent trials more precisely defined the effectiveness of mechanical thrombectomy (modified Rankin Scale 0 to 2; OR = 2.07, 95% CI = 1.70 to 2.51 based on data from eight trials versus OR = 2.39, 95% CI = 1.88 to 3.04 based on data from five trials). Meta-analyses showed no effect on mortality (OR = 0.81, 95% CI = 0.61 to 1.07) or symptomatic intracranial haemorrhage (OR = 1.22, 95% CI = 0.80 to 1.85) as found in analysis of first five trials. Trial sequential analysis indicated that the information size requirement was fulfilled to conclude the evidence for mechanical thrombectomy is robust. DISCUSSION: The impact of three recent trials on effectiveness and safety of mechanical thrombectomy was a more precise pooled effect size for functional independence. Trial sequential analysis demonstrated sufficient evidence for effectiveness and safety of mechanical thrombectomy.
conclusionNo further trials of mechanical thrombectomy versus no mechanical thrombectomy are indicated to establish clinical effectiveness. Uncertainty remains as to whether mechanical thrombectomy reduces mortality or increases risk of symptomatic intracranial haemorrhage.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.