Evidence map›Paper›PMID 31007788›Full record

ArticleJournal of arrhythmia2019

How is Contact Force implemented in routine clinical practice? Results from a French National and Monaco Survey.

Sok-Sithikun Bun, Decebal Gabriel Lațcu, Philippe Taghji, Frederic Anselme, Serge Boveda, Jean-Pierre Cebron, Pascal Defaye, Jean-Claude Deharo, Laurent Fauchier, Estelle Gandjbakhch and 8 more

Abstract read
In one paragraph

Article in Journal of arrhythmia, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

18 authors.

Sok-Sithikun BunDepartment of Cardiology Princess Grace Hospital Monaco (Principality).ORCID https://orcid.org/0000-0003-3016-9192
Decebal Gabriel LațcuDepartment of Cardiology Princess Grace Hospital Monaco (Principality).
Philippe TaghjiPrivate Hospital Clairval Marseille France.
Frederic AnselmeHopital Charles Nicolle Rouen France.
Serge BovedaClinique Pasteur Toulouse France.
Jean-Pierre CebronNouvelles Cliniques Nantaises Nantes France.
Pascal DefayeCHU Grenoble Grenoble France.
Jean-Claude DeharoHôpital La Timone Marseille France.
Laurent FauchierCentre Hospitalier Universitaire Trousseau Tours France.
Estelle GandjbakhchAPHP Pitié Salpêtrière Hospital Cardiology Institute Paris France.
Daniel GrasNouvelles Cliniques Nantaises Nantes France.
Didier KlugCHRU Lille Lille France.
Jacques MansouratiUniversity Hospital of Brest Brest France.
Eloi MarijonPompidou University Hospital Paris France.
Jean-Philippe MauryHopital de Rangueil Toulouse France.
Fabien SquaraCHU Pasteur Nice France.
Nadir SaoudiDepartment of Cardiology Princess Grace Hospital Monaco (Principality).
Jérôme TaïebCentre hospitalier du pays d'Aix Aix en provence France.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundCombination of elementary parameters (force, time, power, impedance drop) has been proposed to optimize radiofrequency (RF) delivery. They have been partially validated in clinical studies.

aimsThe aim of this study was to assess contact-force (CF) implementation into clinical practice.

methodsA 36-question electronic form was sent to 105 electrophysiologists (EP) including some general questions concerning the practice of catheter atrial fibrillation ablation and items concerning the parameters used for CF-guided ablation.

resultsAnswers from 98 EP were collected (93% response rate). The CF-catheters used were Smart Touch, Biosense (52%), Tacticath, Saint-Jude Medical (12%), or both (27%) and no CF (9%). The power applied on the left atrial (LA) anterior (LAAW) and posterior (LAPW) wall was, respectively, 26-34 W (for 73% of the EP) and below 25 W (88% of the EP). Forty percent of the Visitag

conclusionsThe parameters used for CF-guided ablation are widely variable among the different operators. Further prospective studies are needed to validate the targets for automatic annotation of the RF applications.

Indexed as

ablation parameterscontact‐force cathetersradiofrequency ablation

Identifiers

PMID31007788
PMCPMC6457376

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.