Evidence map›Paper›PMID 31007394›Full record

ArticleAutonomous robots2019

Asymptotically Optimal Kinematic Design of Robots using Motion Planning.

Cenk Baykal, Chris Bowen, Ron Alterovitz

Abstract read
In one paragraph

Article in Autonomous robots, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed.

  1. On Surgical Planning of Percutaneous Nephrolithotomy with Patient-Specific CTRs.Medical image computing and computer-assisted intervention : MICCAI ... International Conference on Medical Image Computing and Computer-Assisted Intervention · 2022
    Article
  2. A simulation study to investigate the use of concentric tube robots for epilepsy surgery.Child's nervous system : ChNS : official journal of the International Society for Pediatric Neurosurgery · 2022
    Article
  3. Optimizing Motion-Planning Problem Setup via Bounded Evaluation with Application to Following Surgical Trajectories.Proceedings of the ... IEEE/RSJ International Conference on Intelligent Robots and Systems. IEEE/RSJ International Conference on Intelligent Robots and Systems · 2019
    Article
  4. Design Considerations for a Steerable Needle Robot to Maximize Reachable Lung Volume.IEEE International Conference on Robotics and Automation : ICRA : [proceedings]. IEEE International Conference on Robotics and Automation
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Cenk BaykalMassachusetts Institute of Technology, Cambridge, MA, USA, baykal@mit.edu.
Chris BowenUniversity of North Carolina at Chapel Hill, Chapel Hill, NC, USA, cbbowen@cs.unc.edu.
Ron AlterovitzUniversity of North Carolina at Chapel Hill, Chapel Hill, NC, USA, ron@cs.unc.edu.

Funding

Bronchoscopic Steerable Needles for Transparenchymal Access to Lung NodulesR01EB024864 · NIBIB · UNIV OF NORTH CAROLINA CHAPEL HILL · PI ALTEROVITZ, RON · 2017 to 2021
$2.5M
Robotic Natural Orifice Skull Base SurgeryR01EB017467 · NIBIB · VANDERBILT UNIVERSITY · PI WEBSTER, ROBERT JAMES · 2013 to 2016
$1.7M
Multi-lumen steerable needles for transoral access to lung nodulesR21EB017952 · NIBIB · UNIV OF NORTH CAROLINA CHAPEL HILL · PI ALTEROVITZ, RON · 2013 to 2014
$409k
NIBIB NIH HHS R01 EB017467NIBIB NIH HHS R01 EB024864NIBIB NIH HHS R21 EB017952
6 · The paper itself

Abstract

In highly constrained settings, e.g., a tentaclelike medical robot maneuvering through narrow cavities in the body for minimally invasive surgery, it may be difficult or impossible for a robot with a generic kinematic design to reach all desirable targets while avoiding obstacles. We introduce a design optimization method to compute kinematic design parameters that enable a single robot to reach as many desirable goal regions as possible while avoiding obstacles in an environment. Our method appropriately integrates sampling based motion planning in configuration space into stochastic optimization in design space so that, over time, our evaluation of a design's ability to reach goals increases in accuracy and our selected designs approach global optimality. We prove the asymptotic optimality of our method and demonstrate performance in simulation for (i) a serial manipulator and (ii) a concentric tube robot, a tentacle-like medical robot that can bend around anatomical obstacles to safely reach clinically- relevant goal regions.

Indexed as

Concentric tube robotsDesign optimizationMotion planning

Identifiers

PMID31007394
PMCPMC6472929

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked