Support-Material-Free Microfluidics on an Electrochemical Sensors Platform by Aerosol Jet Printing.

Nicolò Giuseppe Di Novo, Edoardo Cantù, Sarah Tonello, Emilio Sardini, Mauro Serpelloni

Open access · goldAbstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 16 papers.

0numbers the graph read from it
0cells of the map it votes in
16citing papers in PubMed
2.5field-weighted citation impact, top 11% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

16 citing papers in PubMed, 41 citations in OpenAlex.

  1. Aerosol Jet Printing in Biotechnologies.Bioengineering (Basel, Switzerland) · 2026
    Review
  2. Article
  3. Review
  4. Review
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
  10. Article
  11. Review
  12. Article
  13. Article
  14. Article
  15. Article
  16. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 2 institutions in 1 country.

Nicolò Giuseppe Di NovoLaboratory of Bio-Inspired & Graphene Nanomechanics, Department of Civil, Environmental and Mechanical Engineering, University of Trento, Via Mesiano, 77, 38123 Trento, Italy. nicolo.dinovo@unitn.it.
Edoardo CantùDepartment of Information Engineering, University of Brescia, Via Branze 38, 25123 Brescia, Italy. e.cantu@unibs.it.
Sarah TonelloDepartment of Information Engineering, University of Brescia, Via Branze 38, 25123 Brescia, Italy. s.tonello@unibs.it.ORCID 0000-0002-7325-7988
Emilio SardiniDepartment of Information Engineering, University of Brescia, Via Branze 38, 25123 Brescia, Italy. emilio.sardini@unibs.it.ORCID 0000-0001-8629-7316
Mauro SerpelloniDepartment of Information Engineering, University of Brescia, Via Branze 38, 25123 Brescia, Italy. mauro.serpelloni@unibs.it.ORCID 0000-0001-6497-5876
University of Brescia · ITUniversity of Trento · IT

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Printed electronics have led to new possibilities in the detection and quantification of a wide range of molecules important for medical, biotechnological, and environmental fields. The integration with microfluidics is often adopted to avoid hand-deposition of little volumes of reagents and samples on miniaturized electrodes that strongly depend on operator's skills. Here we report design, fabrication and test of an easy-to-use electrochemical sensor platform with microfluidics entirely realized with Aerosol Jet Printing (AJP). We printed a six-electrochemical-sensors platform with AJP and we explored the possibility to aerosol jet print directly on it a microfluidic structure without any support material. Thus, the sacrificial material removal and/or the assembly with sensors steps are avoided. The repeatability observed when printing both conductive and ultraviolet (UV)-curable polymer inks can be supported from the values of relative standard deviation of maximum 5% for thickness and 9% for line width. We designed the whole microfluidic platform to make the sample deposition (20 μL) independent from the operator. To validate the platform, we quantified glucose at different concentrations using a standard enzyme-mediated procedure. Both mediator and enzyme were directly aerosol jet printed on working electrodes (WEs), thus the proposed platform is entirely fabricated by AJP and ready to use. The chronoamperometric tests show limit of detection (LOD) = 2.4 mM and sensitivity = 2.2 ± 0.08 µA/mM confirming the effectiveness of mediator and enzyme directly aerosol jet printed to provide sensing in a clinically relevant range (3-10 mM). The average relative standard inter-platform deviation is about 8%. AJP technique can be used for fabricating a ready-to-use microfluidic device that does not need further processing after fabrication, but is promptly available for electrochemical sample analysis.

Indexed as

3-D printingAerosol Jet Printingglucose sensingsupport-material-free microfluidicsvoltammetric sensors

Identifiers

PMID31003419
PMCPMC6515300
OpenAlexW2938450443

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.