Evidence map›Paper›PMID 30995658›Full record

ArticleAudiology & neuro-otology2019

Comparison of Place-versus-Pitch Mismatch between a Perimodiolar and Lateral Wall Cochlear Implant Electrode Array in Patients with Single-Sided Deafness and a Cochlear Implant.

Jeroen P M Peters, Edwin Bennink, Gijsbert A van Zanten

Abstract readComparative Study
In one paragraph

Article in Audiology & neuro-otology, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed.

  1. Review
  2. Article
  3. Article
  4. Article
  5. Is the spread of excitation width correlated to the speech recognition in cochlear implant users?European archives of oto-rhino-laryngology : official journal of the European Federation of Oto-Rhino-Laryngological Societies (EUFOS) : affiliated with the German Society for Oto-Rhino-Laryngology - Head and Neck Surgery · 2021
    Article
  6. Characterization of the human helicotrema: implications for cochlear duct length and frequency mapping.Journal of otolaryngology - head & neck surgery = Le Journal d'oto-rhino-laryngologie et de chirurgie cervico-faciale · 2020
    Article
  7. Preservation of Residual Hearing: Long-Term Results With a Mid-Scala Electrode.Journal of otolaryngology - head & neck surgery = Le Journal d'oto-rhino-laryngologie et de chirurgie cervico-faciale
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Jeroen P M PetersDepartment of Otorhinolaryngology and Head and Neck Surgery, University Medical Center Utrecht, Utrecht, The Netherlands, h.p.m.peters@umcutrecht.nl.
Edwin BenninkImage Sciences Institute, University Medical Center Utrecht, Utrecht, The Netherlands.
Gijsbert A van ZantenDepartment of Otorhinolaryngology and Head and Neck Surgery, University Medical Center Utrecht, Utrecht, The Netherlands.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundIn electric-acoustic pitch matching experiments in patients with single-sided deafness and a cochlear implant, the observed "mismatch" between perceived pitch and predicted pitch, based on the amended Greenwood frequency map, ranges from -1 to -2 octaves. It is unknown if and how this mismatch differs for perimodiolar versus lateral wall electrode arrays.

objectivesWe aimed to investigate if the type of electrode array design is of influence on the electric-acoustic pitch match.

methodFourteen patients (n = 8 with CI422 + lateral wall electrode array, n = 6 with CI512 + perimodiolar electrode array; Cochlear Ltd.) compared the pitch of acoustic stimuli to the pitch of electric stimuli at two test sessions (average interval 4.3 months). We plotted these "pitch matches" per electrode contact against insertion angle, calculated from high-resolution computed tomography scans. The difference between these pitch matches and two references (the spiral ganglion map and the default frequency allocation by Cochlear Ltd.) was defined as "mismatch."

resultsWe found average mismatches of -2.2 octaves for the CI422 group and -1.3 octaves for the CI512 group. For any given electrode contact, the mismatch was smaller for the CI512 electrode array than for the CI422 electrode array. For all electrode contacts together, there was a significant difference between the mismatches of the two groups (p < 0.05). Results remained stable over time, with no significant difference between the two test sessions considering all electrode contacts. Neither group showed a significant correlation between the mismatch and phoneme recognition scores.

conclusionThe pitch mismatch was smaller for the perimodiolar electrode array than for the lateral wall electrode array.

Indexed as

Cochlear ImplantsPitch PerceptionAcoustic StimulationAdultAgedCochlear ImplantationDeafnessElectrodes, ImplantedFemaleHearing Loss, UnilateralHumansMaleMiddle AgedSpiral GanglionTreatment OutcomeYoung AdultCochlear implantContour advanceElectric-acoustic pitch matchFrequency-place mapHearing lossLateral wall electrodeModiolar huggingPerimodiolar electrode arrayPlace-versus-pitchSingle-sided deafness

Identifiers

PMID30995658
PMCPMC6549524

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.