Evidence map›Paper›PMID 30994599›Full record

ArticleSpine2019

Mechanical Performance of Posterior Spinal Instrumentation and Growing Rod Implants: Experimental and Computational Study.

Mary H Foltz, Andrew L Freeman, Galyna Loughran, Joan E Bechtold, Victor H Barocas, Arin M Ellingson, David W Polly

Abstract read
In one paragraph

Article in Spine, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed.

  1. Article
  2. Investigation of instrumentation lengthening in the thoracolumbar junction of the spine - an in vitro Biomechanical study.European spine journal : official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society · 2025
    Article
  3. Article
  4. Article
  5. Simulation and validation of spinal construct testing based on ASTM F1717.Frontiers in bioengineering and biotechnology · 2025
    Article
  6. Current benchtop protocols are not appropriate for the evaluation of distraction-based growing rods: a literature review to justify a new protocol and its development.European spine journal : official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society · 2022
    Review
  7. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Mary H FoltzDepartment of Biomedical Engineering, College of Science and Engineering, University of Minnesota, Minneapolis, Minnesota.
Andrew L FreemanDepartment of Biomedical Engineering, College of Science and Engineering, University of Minnesota, Minneapolis, Minnesota.
Galyna LoughranExcelen Center for Bone & Joint Research and Education, Minneapolis, Minnesota.
Joan E BechtoldDepartment of Biomedical Engineering, College of Science and Engineering, University of Minnesota, Minneapolis, Minnesota.
Victor H BarocasDepartment of Biomedical Engineering, College of Science and Engineering, University of Minnesota, Minneapolis, Minnesota.
Arin M EllingsonDepartment of Orthopaedic Surgery, Medical School, University of Minnesota, Minneapolis, Minnesota.
David W PollyDepartment of Orthopaedic Surgery, Medical School, University of Minnesota, Minneapolis, Minnesota.

Funding

Interdisciplinary Engineering Career Development Center in Movement and Rehabilitation SciencesK12HD073945 · NICHD · NORTHWESTERN UNIVERSITY AT CHICAGO · PI DEWALD, JULIUS P, REINKENSMEYER, DAVID JAY · 2012 to 2021
$7.9M
NICHD NIH HHS K12 HD073945
6 · The paper itself

Abstract

STUDY

designExperimental and computational study of posterior spinal instrumentation and growing rod constructs per ASTM F1717-15 vertebrectomy methodology for static compressive bending.

objectiveAssess mechanical performance of standard fusion instrumentation and growing rod constructs. SUMMARY OF BACKGROUND DATA: Growing rod instrumentation utilizes fewer anchors and spans longer distances, increasing shared implant loads relative to fusion. There is a need to evaluate growing rod's mechanical performance. ASTM F1717-15 standard assesses performance of spinal instrumentation; however, effects of growing rods with side-by-side connectors have not been evaluated.

methodsStandard and growing rod constructs were tested per ASTM F1717-15 methodology; setup was modified for growing rod constructs to allow for connector offset. Three experimental groups (standard with active length 76 mm, and growing rods with active lengths 76 and 376 mm; n = 5/group) were tested; stiffness, yield load, and load at maximum displacement were calculated. Computational models were developed and used to locate stress concentrations.

resultsFor both constructs at 76 mm active length, growing rod stiffness (49 ± 0.8 N/mm) was significantly greater than standard (43 ± 0.4 N/mm); both were greater than growing rods at 376 mm (10 ± 0.3 N/mm). No significant difference in yield load was observed between growing rods (522 ± 12 N) and standard (457 ± 19 N) constructs of 76 mm. Growing rod constructs significantly decreased from 76 mm (522 ± 12 N) to 376 mm active length (200 ± 2 N). Maximum load of growing rods at 76 mm (1084 ± 11 N) was significantly greater than standard at 76 mm (1007 ± 7 N) and growing rods at 376 mm active length (392 ± 5 N). Simulations with active length of 76 mm were within 10% of experimental mechanical characteristics; stress concentrations were at the apex and cranial to connector-rod interaction for standard and growing rod models, respectively.

conclusionGrowing rod constructs are stronger and stiffer than spinal instrumentation constructs; with an increased length accompanied a decrease in strength. Growing rod construct stress concentration locations observed during computational simulation are consistent with clinically observed failure locations. LEVEL OF EVIDENCE: 5.

Indexed as

Prostheses and ImplantsBiomechanical PhenomenaFracture Fixation, InternalHumansSpinal FusionStress, Mechanical

Identifiers

PMID30994599
PMCPMC6722018

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.