Evidence map›Paper›PMID 30993642›Full record

ArticleJournal of the American Society for Mass Spectrometry2019

Determination of Gas-Phase Ion Structures of Locally Polar Homopolymers Through High-Resolution Ion Mobility Spectrometry-Mass Spectrometry.

Xi Chen, Shannon A Raab, Timothy Poe, David E Clemmer, Carlos Larriba-Andaluz

Abstract read
PubMed Publisher
In one paragraph

Article in Journal of the American Society for Mass Spectrometry, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Xi ChenDepartment of Mechanical Engineering, IUPUI, 723 W Michigan st, Indianapolis, IN, 46202, USA.
Shannon A RaabDepartment of Chemistry, Indiana University, 800 E Kirkwood Ave, Bloomington, IN, 47405, USA.
Timothy PoeDepartment of Mechanical Engineering, IUPUI, 723 W Michigan st, Indianapolis, IN, 46202, USA.
David E ClemmerDepartment of Chemistry, Indiana University, 800 E Kirkwood Ave, Bloomington, IN, 47405, USA.
Carlos Larriba-AndaluzDepartment of Mechanical Engineering, IUPUI, 723 W Michigan st, Indianapolis, IN, 46202, USA. clarriba@iupui.edu.ORCID http://orcid.org/0000-0003-0864-7733

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The strong synergy arising from coupling two orthogonal analytical techniques such as ion mobility and mass spectrometry can be used to separate complex mixtures and determine structural information of analytes in the gas phase. A tandem study is performed using two systems with different gases and pressures to ascertain gas-phase conformations of homopolymer ions. Aside from spherical and stretched configurations, intermediate configurations formed by a multiply charged globule and a "bead-on-a-string" appendix are confirmed for polyethylene-glycol (PEG), polycaprolactone (PCL), and polydimethylsiloxane (PDMS). These intermediate configurations are shown to be ubiquitous for all charge states and masses present. For each charge state, configurations evolve in two distinctive patterns: an inverse evolution which occurs as an elementary charge attached to the polymer leaves the larger globule and incorporates itself into the appendage, and a forward evolution which reduces the globule without relinquishing a charge while leaving the appendix relatively constant. Forward evolutions are confirmed to form self-similar family shapes that transcend charge states for all polymers. Identical structural changes occur at the same mass over charge regardless of the system, gas or pressure strongly suggesting that conformations are only contingent on number of charges and chain length, and start arranging once the ion is at least partially ejected from the droplet, supporting a charge extrusion mechanism. Configurational changes are smoother for PDMS which is attributed to the larger steric hindrance caused by protruding pendant groups. This study has implications in the study of the configurational space of more complex homopolymers and heteropolymers. Graphical Abstract.

Indexed as

DMAdrift tubeHomopolymerIMS-MSIMS, polymerIon Mobility SpectrometryMass SpectrometryPCLPDMSPEGPolycaprolactonePolydimethylsiloxanePolyethylene-glycolStructure

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.