Evidence map›Paper›PMID 30990314›Full record

ArticleACS sensors2019

Ultrasensitive Detection of Hepatotoxic Microcystin Production from Cyanobacteria Using Surface-Enhanced Raman Scattering Immunosensor.

Ming Li, Santosh Kumar Paidi, Eric Sakowski, Sarah Preheim, Ishan Barman

Open access · greenAbstract read
In one paragraph

Article in ACS sensors, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 10 papers.

0numbers the graph read from it
0cells of the map it votes in
10citing papers in PubMed
4.5field-weighted citation impact, top 5% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

10 citing papers in PubMed, 69 citations in OpenAlex.

  1. Article
  2. Review
  3. Review
  4. Article
  5. Review
  6. Review
  7. Review
  8. Review
  9. Review
  10. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 2 institutions in 2 countries.

Ming LiSchool of Materials Science and Engineering, State Key Laboratory for Power Metallurgy , Central South University , Changsha , Hunan 410083 , China.ORCID 0000-0002-2289-0222
Santosh Kumar Paidi
Eric Sakowski
Sarah Preheim
Johns Hopkins University · USCentral South University · CN

Funding

Wide-Field Short-Wave Infrared (SWIR) multiphoton (MP) tissue imagingP41EB015871 · NIBIB · MASSACHUSETTS INSTITUTE OF TECHNOLOGY · PI SO, PETER T. · 2012 to 2021
$11.3M
Spectroscopy assisted mechano-chemical phenotype recognition nanoscopeDP2GM128198 · NIGMS · JOHNS HOPKINS UNIVERSITY · PI BARMAN, ISHAN · 2017 to 2017
$2.5M
NIBIB NIH HHS P41 EB015871NIGMS NIH HHS DP2 GM128198
6 · The paper itself

Abstract

Microcystin-LR (MC-LR) is considered the most common hazardous toxin produced during harmful algal blooms. In addition to potential risk of long-term exposure to low concentrations in drinking water, acute toxicity due to MC-LR resulting from algal blooms could result in fatalities in rare cases. Although several methods are currently available to detect MC-LR, development of a low-cost, ultrasensitive measurement method would help limit exposure by enabling early detection and continuous monitoring of MC-LR. Here, we develop a surface-enhanced Raman scattering (SERS) spectroscopic immunosensor for detection and quantification of the hepatotoxic MC-LR toxin in aquatic settings with excellent robustness, selectivity, and sensitivity. We demonstrate that the developed SERS sensor can reach a limit of detection (0.014 μg/L) at least 1 order of magnitude lower and display a linear dynamic detection range (0.01 μg/L to 100 μg/L) 2 orders of magnitude wider in comparison to the commercial enzyme-linked immunosorbent assay test. The superior analytical performance of this SERS immunosensor enables monitoring of the dynamic production of MC-LR from a Microcystis aeruginosa culture. We believe that the present method could serve as a useful tool for detection of hepatotoxic microcystin toxins in various aquatic settings such as drinking water, lakes, and reservoirs. Further development of this technique could result in single-cell microcystin resolution or real-time monitoring to mitigate the associated toxicity and economic loss.

Indexed as

Limit of DetectionBiosensing TechniquesCyanobacteriaImmunoassayLakesLiverMicrocystinsSpectrum Analysis, RamanWatermicrocystinMicrocystinsWateralgal bloomsbiosensorsmicrocystin-LRsurface-enhanced Raman scatteringtoxins

Identifiers

PMID30990314
PMCPMC6776237
OpenAlexW2938195279

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.