Determination of Gas-Phase Ion Mobility Coefficients Using Voltage Sweep Multiplexing.
Article in Journal of the American Society for Mass Spectrometry, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 14 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
14 citing papers in PubMed.
- Asynchronous Stepped Fourier Transform Ion Mobility Spectrometry.Journal of the American Society for Mass Spectrometry · 2026Article
- Solving the "General Elution Problem" of Ion Mobility Spectrometry: Single-Run Voltage Sweep.Analytical chemistry · 2025Article
- Reliable Detection of Chemical Warfare Agents Using High Kinetic Energy Ion Mobility Spectrometry.Journal of the American Society for Mass Spectrometry · 2024Article
- Development of a Modular, Open-Source, Reduced-Pressure, Drift Tube Ion Mobility Spectrometer.Journal of the American Society for Mass Spectrometry · 2024Article
- Implementation of an Open-Source Multiplexing Ion Gate Control for High Kinetic Energy Ion Mobility Spectrometry (HiKE-IMS).Journal of the American Society for Mass Spectrometry · 2023Article
- FTflow: An Open-Source Python GUI for FT-IM-MS Experiments.Journal of the American Society for Mass Spectrometry · 2023Article
- A Comparison of the Performance of Modular Standalone Do-It-Yourself Ion Mobility Spectrometry Systems.Journal of the American Society for Mass Spectrometry · 2023Article
- Article
- Considerations for Generating Frequency Modulation Waveforms for Fourier Transform-Ion Mobility Experiments.Journal of the American Society for Mass Spectrometry · 2022Article
- Exploring the Conformations and Binding Location of HMGA2·DNA Complexes Using Ion Mobility Spectrometry and 193 nm Ultraviolet Photodissociation Mass Spectrometry.Journal of the American Society for Mass Spectrometry · 2022Article
- Synchronized Stepped Frequency Modulation for Multiplexed Ion Mobility Measurements.Journal of the American Society for Mass Spectrometry · 2022Article
- Implementing Digital-Waveform Technology for ExtendedJournal of the American Society for Mass Spectrometry · 2021Article
- Ion Mobility Spectrometry with High Ion Utilization Efficiency Using Traveling Wave-Based Structures for Lossless Ion Manipulations.Analytical chemistry · 2020Article
- Validation of Calibration Parameters for Trapped Ion Mobility Spectrometry.Journal of the American Society for Mass Spectrometry · 2019Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
3 authors.
Funding
Abstract
In a standard single averaged, drift tube ion mobility spectrometry (IMS) experiment, typically less than 1% of the ions are utilized, with the rest of the ions neutralizing on a closed ion gate or ion optic element. Though some efforts at lower pressures (e.g., 4 Torr) have been made to address this issue by concentrating ions prior to release into a drift cell, the ion current reaching the detector during an IMS experiment is often diminished due to this lower duty cycle. Additionally, when considering the temporal nature of the drift tube IMS experiment and the trajectory of IMS towards higher resolution separations and lower duty cycles, increased detector sampling rates are another factor also which further necessitates new modes of conducting the IMS experiment. Placing this trend in context with ion mobility-mass spectrometry instruments (IM-MS), there are numerous types of mass spectrometers that are simply incompatible with the single averaged ion mobility spectrometry experiments due to timing incompatibilities (i.e., ion traps are an order of magnitude slower than the IMS experiment). However, by utilizing a dual gate ion mobility spectrometer for ion multiplexing, ion utilization efficiency can be significantly increased while creating a measurement signal that can be recorded at low sampling rates. In this work, we present the fundamental theory and first results from proof-of-concept measurements using a new type of ion multiplexing that relies on changing the electric field within the drift cell during the course of an experiment while simultaneously opening the ion gates at a constant frequency. For brevity, this mode is termed voltage sweep multiplexing (VSM). Key variables for this type of experiment are discussed and verified with measurements from traditional signal averaged experiments. Graphical Abstract .
Indexed as
Identifiers
30989619What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.