ReviewHerzschrittmachertherapie & Elektrophysiologie2019
[Device-device interaction].
Review in Herzschrittmachertherapie & Elektrophysiologie, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
2 citing papers in PubMed, 5 citations in OpenAlex.
- One heart, seven leads: A case report of complex cardiac device therapy in a patient with chemotherapy-induced toxic cardiomyopathy.HeartRhythm case reports · 2025Article
- Enhancing myocardial function with cardiac contractility modulation: potential and challenges.ESC heart failure · 2024Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
3 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
With a continuous increase in the approval of cardiac implantable electronic devices (CIED), not only pacemakers (PM) and implantable cardioverter defibrillators (ICD) but especially devices for treating chronic heart failure, more and more possibilities of device-device interactions arise, which in isolated cases can lead to death of the patient. Because of the still low numbers of patients overall, there are very few scientific studies and only isolated case reports on this topic. Devices which are at risk of interaction with a previously implanted PM are wearable cardioverter defibrillators (WCD) and subcutaneous ICDs (S-ICD). These two devices both use the surface electrocardiogram (ECG) in their algorithm for detecting ventricular arrhythmia. These surface ECGs seem to be prone to unipolar pacemaker stimulation artefacts. By correct programming of implanted pacemakers in the bipolar stimulation mode it is possible to avoid ECG artefacts and inadequate treatment. In baroreceptor activation therapy (BAT) there seem to be no device interactions so far, even though this device shows substantial highly frequent artefacts in the ECG. The cardiac contractility modulation (CCM) system has also until now not shown interactions with transvenous or subcutaneous ICD devices, even though randomized trials are missing.