Evidence map›Paper›PMID 30989056›Full record

ArticleMethodsX2019

The investigation of type and concentration of bio-aerosols in the air of surgical rooms: A case study in Shariati hospital, Karaj.

Zahra Tolabi, Mahmood Alimohammadi, Mohammad Sadegh Hassanvand, Ramin Nabizadeh, Hamed Soleimani, Ahmad Zarei

Open access · goldAbstract read
In one paragraph

Article in MethodsX, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed
1.5field-weighted citation impact, top 21% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed, 24 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Review
  6. Article
  7. Article
  8. The Dose of Fungal Aerosol Inhaled by Workers in a Waste-Sorting Plant in Poland: A Case Study.International journal of environmental research and public health · 2019
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 2 institutions in 1 country.

Zahra TolabiDepartment of Environmental Health Engineering, School of Public Health, Tehran University of Medical Sciences, Tehran, Iran.
Mahmood AlimohammadiDepartment of Environmental Health Engineering, School of Public Health, Tehran University of Medical Sciences, Tehran, Iran.
Mohammad Sadegh HassanvandDepartment of Environmental Health Engineering, School of Public Health, Tehran University of Medical Sciences, Tehran, Iran.
Ramin NabizadehDepartment of Environmental Health Engineering, School of Public Health, Tehran University of Medical Sciences, Tehran, Iran.
Hamed SoleimaniDepartment of Environmental Health Engineering, School of Public Health, Tehran University of Medical Sciences, Tehran, Iran.
Ahmad ZareiDepartment of Environmental Health Engineering, School of Public Health, Gonabad University of Medical Sciences, Gonabad, Iran.
Tehran University of Medical Sciences · IRGonabad University of Medical Sciences · IR

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The presence of bio-aerosols is one of the main causes of hospital infections that can be dangerous especially for immunocompromised patients. This research aimed to determine the relationship between hospital infections and surgical incision size in addition to determining the concentration and bacterial and fungal bioaerosols found in the operating rooms. This cross-sectional descriptive-analytic study was carried out in the operating rooms of Shariati Hospital in Karaj, Iran during the years 2016 and 2017. A total of 198 bacterial samples and 198 fungal samples were collected and analyzed using a passive sampling standard method (1/1/1) for 180 days. Tryptic Soy Agar (TSA) and Sabouraud Dextrose Agar (SDA) medium were used for bacterial and fungal samples, respectively. Relevant differential tests were used to determine the genus and species of bacteria and fungi such as DNase test, Bile-esculin, motility test urease test. In general, this work presents: •The present evaluated the relationship between bioaerosols concentration and surgical incision size.•The intraoperative concentration of bacterial and fungal bioaerosols in indoor air of the orthopedic, internal and cesarean operating rooms was significantly higher than their preoperative concentration (p-value<0.05).•Also, there was not significant difference between the bacterial and fungal concentrations in various operating rooms) p-value<0.05).

Indexed as

AspergilluBacteriaBioaerosolFungiHospital infectionsIndoor air pollutantType and concentration of bio-aerosols

Identifiers

PMID30989056
PMCPMC6447748
OpenAlexW2924864507

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.