Evidence map›Paper›PMID 30988794›Full record

ArticleExperimental and therapeutic medicine2019

Ultra-low dose one-step CT angiography for coronary, carotid and cerebral arteries using 128-slice dual-source CT: A feasibility study.

Lei Zhao, Jiaqi Bao, Youmin Guo, Jianbo Li, Xiaoguang Yang, Tiegang Lv, Fen'E Hao, Zefeng Wang, Zhenxing Yang, Aishi Liu

Abstract read
In one paragraph

Article in Experimental and therapeutic medicine, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed.

  1. Trial
  2. Article
  3. Review
  4. Article
  5. Article
  6. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors.

Lei ZhaoDepartment of Radiology, The Affiliated Hospital of Inner Mongolia Medical University, Hohhot, Inner Mongolia 010050, P.R. China.
Jiaqi BaoDepartment of Cardiology, Inner Mongolia People's Hospital, Hohhot, Inner Mongolia 010020, P.R. China.
Youmin GuoDepartment of Radiology, The Affiliated Hospital of Xi'an Jiaotong University, Xi'an, Shaanxi 710061, P.R. China.
Jianbo LiDepartment of Radiology, The Affiliated Hospital of Inner Mongolia Medical University, Hohhot, Inner Mongolia 010050, P.R. China.
Xiaoguang YangDepartment of Radiology, The Affiliated Hospital of Inner Mongolia Medical University, Hohhot, Inner Mongolia 010050, P.R. China.
Tiegang LvDepartment of Radiology, The Affiliated Hospital of Inner Mongolia Medical University, Hohhot, Inner Mongolia 010050, P.R. China.
Fen'E HaoDepartment of Radiology, The Affiliated Hospital of Inner Mongolia Medical University, Hohhot, Inner Mongolia 010050, P.R. China.
Zefeng WangDepartment of Radiology, The Affiliated Hospital of Inner Mongolia Medical University, Hohhot, Inner Mongolia 010050, P.R. China.
Zhenxing YangDepartment of Radiology, The Affiliated Hospital of Inner Mongolia Medical University, Hohhot, Inner Mongolia 010050, P.R. China.
Aishi LiuDepartment of Radiology, The Affiliated Hospital of Inner Mongolia Medical University, Hohhot, Inner Mongolia 010050, P.R. China.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Atherosclerotic diseases are systemic and patient outcomes depend on comprehensive imaging evaluation. Computed tomography angiography (CTA) is a powerful tool used to assess atherosclerosis. However, the scanning protocol is designed for cardiovascular and cerebrovascular imaging, which require considerations into the radiation dose, contrast agent and image quality. The purpose of the present study was to evaluate ultra-low dose one-step CTA for coronary, carotid and cerebral arteries with a low concentration contrast agent. A total of 78 patients were enrolled and randomly divided into two groups: Group A (n=38) and B (n=40). High-pitch CTA for coronary, carotid and cerebral arteries with a tube voltage of 70 or 80 kVp and 40 ml contrast agent (270 mgI/ml) was performed by a 128-slice dual-source CT scanner for group A. Standard high-pitch CTA with a tube voltage of 100 kVp and 60 ml contrast agent (370 mgI/ml) was conducted for group B. The image quality, radiation dose and amount of contrast agent in group A were evaluated and compared with group B. The dose length product for groups A and B was 62.95±21.54 vs. 160.15±15.13 mGy cm, respectively (t=-23.157, P<0.001). The mean total iodine content was 10.8±0 mg for group A and 22.2±0 mg for group B. In total, 99.4% of the arterial segments could be assessed for the two groups (

Indexed as

computed tomography angiographycontrast agenthigh-pitch scanimage qualityradiation dose

Identifiers

PMID30988794
PMCPMC6447913