Evidence map›Paper›PMID 30983957›Full record

ReviewFrontiers in neuroscience2019

Bioactive Neuroelectronic Interfaces.

Dayo O Adewole, Mijail D Serruya, John A Wolf, D Kacy Cullen

Abstract readReview
In one paragraph

Review in Frontiers in neuroscience, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 17 papers.

0numbers the graph read from it
0cells of the map it votes in
17citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

17 citing papers in PubMed.

  1. Review
  2. Review
  3. Review
  4. Article
  5. Review
  6. Review
  7. Article
  8. Review
  9. Article
  10. Article
  11. Review
  12. Review
  13. Article
  14. Article
  15. Article
  16. The Future of Neuroscience: Flexible and Wireless Implantable Neural Electronics.Advanced science (Weinheim, Baden-Wurttemberg, Germany) · 2021
    Review
  17. Assessing the Feasibility of DevelopingFrontiers in neuroscience · 2021
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Dayo O AdewoleCenter for Brain Injury and Repair, Department of Neurosurgery, Perelman School of Medicine, University of Pennsylvania, Philadelphia, PA, United States.
Mijail D SerruyaDepartment of Neurology, Thomas Jefferson University, Philadelphia, PA, United States.
John A WolfCenter for Brain Injury and Repair, Department of Neurosurgery, Perelman School of Medicine, University of Pennsylvania, Philadelphia, PA, United States.
D Kacy CullenCenter for Brain Injury and Repair, Department of Neurosurgery, Perelman School of Medicine, University of Pennsylvania, Philadelphia, PA, United States.

Funding

Training Program in Neuroengineering and MedicineT32NS091006 · NINDS · UNIVERSITY OF PENNSYLVANIA · PI Brian Litt · 2015 to 2026
$4.1M
Biological 'Living Electrodes' Using Tissue Engineered Axonal Tracts to Probe and Modulate the Nervous SystemU01NS094340 · NINDS · UNIVERSITY OF PENNSYLVANIA · PI CULLEN, DANIEL KACY · 2015 to 2017
$2.0M
Transplantable Micro-Tissue Engineered Neural Networks to Restore the Nigrostriatal Pathway in Parkinson's DiseaseI01BX003748 · VA · PHILADELPHIA VA MEDICAL CENTER · PI CULLEN, DANIEL KACY · 2017 to 2022
–
BLRD VA I01 BX003748NINDS NIH HHS T32 NS091006NINDS NIH HHS U01 NS094340
6 · The paper itself

Abstract

Within the neural engineering field, next-generation implantable neuroelectronic interfaces are being developed using biologically-inspired and/or biologically-derived materials to improve upon the stability and functional lifetime of current interfaces. These technologies use biomaterials, bioactive molecules, living cells, or some combination of these, to promote host neuronal survival, reduce the foreign body response, and improve chronic device-tissue integration. This article provides a general overview of the different strategies, milestones, and evolution of bioactive neural interfaces including electrode material properties, biological coatings, and "decoration" with living cells. Another such biohybrid approach developed in our lab uses preformed implantable micro-tissue featuring long-projecting axonal tracts encased within carrier biomaterial micro-columns. These so-called "living electrodes" have been engineered with carefully tailored material, mechanical, and biological properties to enable natural, synaptic based modulation of specific host circuitry while ultimately being under computer control. This article provides an overview of these living electrodes, including design and fabrication, performance attributes, as well as findings to date characterizing

Indexed as

biomaterialsneural engineeringneuroprostheticsneurotechnology and brain-machine interfacetissue engineering

Identifiers

PMID30983957
PMCPMC6449725

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.