ArticleDento maxillo facial radiology2019
Influence of the incorporation of a lead foil to intraoral digital receptors on the image quality and root fracture diagnosis.
Article in Dento maxillo facial radiology, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
9 citing papers in PubMed, 21 citations in OpenAlex.
- Does facial sunscreen usage impact radiographic image quality and radiation dose? An in vitro study.Oral radiology · 2025Article
- Comparison of objective radiograph quality between radiographs obtained with wall-mounted and handheld X-ray devices.Imaging science in dentistry · 2025Article
- A comparative investigation of the quality of radiographs produced by portable handheld and fixed x-ray units.Brazilian dental journal · 2025Article
- Benefits of using a photostimulable phosphor plate protective device.Dento maxillo facial radiology · 2021Article
- Influence of the image file format of digital periapical radiographs on the diagnosis of external and internal root resorptions.Clinical oral investigations · 2021Article
- Digital subtraction radiography in detection of vertical root fractures: accuracy evaluation for root canal filling, fracture orientation and width variables. An ex-vivo study.Clinical oral investigations · 2020Article
- Does the addition of a lead foil to digital radiographic receptors influence image contrast and approximal caries lesions diagnosis?Dento maxillo facial radiology · 2020Article
- Could the radiographic image quality be affected by the excessive use of the photostimulable phosphor plate?Brazilian dental journalArticle
- DICOM file format has better radiographic image quality than other file formats: an objective study.Brazilian dental journalArticle
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
objectiveTo evaluate the quality of images obtained with the addition of a lead foil to intraoral digital receptors.
methodsRadiographic images of 34 single-rooted human teeth - 19 with vertical root fracture (VRF) and 15 of the control group - were obtained with and without the addition of a lead foil, using the VistaScan, Express, Digora Optime and Digora Toto systems. Images were evaluated by five observers regarding the diagnosis of VRF, using a 5-point scale. In a second moment, an observer preference analysis related to the presence of the lead foil was performed. Images of an acrylic phantom were also obtained with and without the addition of a lead foil, and the quantities of uniformity, grey value and standard deviation of grey values were obtained.
resultsThere were no significant differences in the VRF diagnostic values, considering the presence of the lead foil. Regarding the image quality preference, the observers preferred images acquired with the lead foil for all systems tested, but with greater values for Digora Optime (61.33%) and Express (61.33%). The presence of the lead foil did influence the image uniformity in all systems tested (
conclusionThe addition of a lead foil to intraoral digital receptors produces a positive effect in the image quality objectively detected by means of uniformity and subjective visual preference.