Measuring clinically relevant knee motion with a self-calibrated wearable sensor.

Todd J Hullfish, Feini Qu, Brendan D Stoeckl, Peter M Gebhard, Robert L Mauck, Josh R Baxter

Open access · greenAbstract read
In one paragraph

Article in Journal of biomechanics, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
0.8field-weighted citation impact, top 30% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed, 12 citations in OpenAlex.

  1. Review
  2. Article
  3. Article
  4. Wearable Tendon Kinetics.Sensors (Basel, Switzerland) · 2020
    Article
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 2 institutions in 1 country.

Todd J HullfishDepartment of Orthopaedic Surgery, Perelman School of Medicine, University of Pennsylvania, Philadelphia, PA, USA.
Feini QuDepartment of Orthopaedic Surgery, Perelman School of Medicine, University of Pennsylvania, Philadelphia, PA, USA; Translational Musculoskeletal Research Center, Corporal Michael J. Crescenz VA Medical Center, Philadelphia, PA, USA.
Brendan D StoecklDepartment of Orthopaedic Surgery, Perelman School of Medicine, University of Pennsylvania, Philadelphia, PA, USA.
Peter M GebhardDepartment of Orthopaedic Surgery, Perelman School of Medicine, University of Pennsylvania, Philadelphia, PA, USA.
Robert L MauckDepartment of Orthopaedic Surgery, Perelman School of Medicine, University of Pennsylvania, Philadelphia, PA, USA; Translational Musculoskeletal Research Center, Corporal Michael J. Crescenz VA Medical Center, Philadelphia, PA, USA.
Josh R BaxterDepartment of Orthopaedic Surgery, Perelman School of Medicine, University of Pennsylvania, Philadelphia, PA, USA. Electronic address: josh.baxter@uphs.upenn.edu.
University of Pennsylvania · USPhiladelphia VA Medical Center · US

Funding

Overall: Resource-based Center for Musculoskeletal Disorders Research (Overall Application)P30AR069619 · NIAMS · UNIVERSITY OF PENNSYLVANIA · PI LOUIS J SOSLOWSKY · 2016 to 2026
$9.1M
Training Program in Musculoskeletal ResearchT32AR007132 · NIAMS · UNIVERSITY OF PENNSYLVANIA · PI Robert L Mauck, LOUIS J SOSLOWSKY · 1986 to 2026
$4.9M
NIAMS NIH HHS P30 AR069619NIAMS NIH HHS T32 AR007132
6 · The paper itself

Abstract

Low-cost sensors provide a unique opportunity to continuously monitor patient progress during rehabilitation; however, these sensors have yet to demonstrate the fidelity and lack the calibration paradigms necessary to be viable tools for clinical research. The purpose of this study was to validate a low-cost wearable sensor that accurately measured peak knee extension during clinical exercises and needed no additional equipment for calibration. Sagittal plane knee motion was quantified using a 9-axis motion sensor and directly compared to motion capture data. The motion sensor measured the field strength of a strong earth magnet secured to the distal femur, which was correlated with knee angle during a simple calibration process. Peak knee motions and kinematic patterns were compared with motion capture data using paired t-tests and cross correlation, respectively. Peak extension values during seated knee extensions were accurate within 5 degrees across all subjects (root mean square error: 2.6 degrees, P = 0.29). Knee flexion during gait strongly correlated (0.84 ≤ r

Indexed as

MovementWearable Electronic DevicesAdultBiomechanical PhenomenaCalibrationFemurGaitHumansKneeMaleMonitoring, PhysiologicInertial measurement unitLow-cost sensorMotion captureWearable sensors