Cherenkov-excited luminescence scanned imaging using scanned beam differencing and iterative deconvolution in dynamic plan radiation delivery in a human breast phantom geometry.

Mengyu Jeremy Jia, Petr Bruza, Jacqueline M Andreozzi, Lesley A Jarvis, David J Gladstone, Brian W Pogue

Abstract read
In one paragraph

Article in Medical physics, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed.

  1. Review
  2. Article
  3. Article
  4. High-Resolution pOInternational journal of radiation oncology, biology, physics · 2021
    Article
  5. Review
  6. Review
  7. Article
  8. Tissue pONature communications · 2020
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Mengyu Jeremy JiaThayer School of Engineering, Dartmouth College, Hanover, NH, 03755, USA.
Petr BruzaThayer School of Engineering, Dartmouth College, Hanover, NH, 03755, USA.
Jacqueline M AndreozziThayer School of Engineering, Dartmouth College, Hanover, NH, 03755, USA.
Lesley A JarvisDepartment of Medicine, Geisel School of Medicine, Dartmouth College, Hanover, NH, 03755, USA.
David J GladstoneThayer School of Engineering, Dartmouth College, Hanover, NH, 03755, USA.
Brian W PogueThayer School of Engineering, Dartmouth College, Hanover, NH, 03755, USA.

Funding

Cerenkov excited luminescence sheet imaging (CELSI)R01EB024498 · NIBIB · DARTMOUTH COLLEGE · PI POGUE, BRIAN WILLIAM · 2017 to 2020
$2.2M
Congressionally Directed Medical Research Program W81XWH-16-1-0004NIBIB NIH HHS R01 EB024498NIH HHS R01 EB024498
6 · The paper itself

Abstract

purposeThe purpose of this study was to demonstrate high resolution optical luminescence sensing, referred to as Cherenkov excited luminescence scanning imaging (CELSI), could be achieved during a standard dynamic treatment plan for a whole breast radiotherapy geometry.

methodsThe treatment plan beams induce Cherenkov light within tissue, and this excitation projects through the beam trajectory across the medium, inducing luminescence where there can be molecular reporter. Broad beams generally produce higher signal but low spatial resolution, yet for dynamic plans the scanning of the multileaf collimator allows for a beam-narrowing strategy by recursively temporal differencing each of the Cherenkov images and associated luminescence images. Then reconstruction from each of these size-reduced beamlets defined by the differenced Cherenkov images provides a well-conditioned matrix inversion, where the spatial frequencies are limited by the higher signal-to-noise ratio beamlets. A built-in stepwise convergence relies on stepwise beam size reduction, which is associated with a widening of the bandwidth of Cherenkov spatial frequency and resultant increase in spatial resolution. For the phantom experiments, europium nanoparticles were used as luminescent probes and embedded at depths ranging from 3 to 8 mm. An intensity modulated radiotherapy (IMRT) plan was used to test this.

resultsThe Cherenkov images spatially guided where the luminescence was measured from, providing high lateral resolution, and iterative reconstruction convergence showed that optimization of the initial and stopping beamlet widths could be achieved with 15 and 4.5 mm, respectively, using a luminescence imaging frame rate of 5/s. With the IMRT breast plan, the original lateral resolution was improved 2X, that is, 0.08-0.24 mm for target depths of 3-8 mm. In comparison, a dynamic wedge (DW) plan showed an inferior image fidelity, with relative contrast recovery decreasing from 0.86 to 0.79. The methodology was applied to a three-dimensional dataset to reconstruct Cherenkov excited luminescence intensity distributions showing volumetric recovery of a 0.5 mm diameter object composed of 0.5 μM luminescent microbeads.

conclusionsHigh resolution CELSI was achieved with a clinical breast external beam radiotherapy (EBRT) plan. It is anticipated that this method can allow visualization and localization for luminescence/fluorescence tagged vasculature, lymph nodes, or superficial tagged regions with most dynamic treatment plans.

Indexed as

LuminescencePhantoms, ImagingBreastHumansRadiotherapy, Intensity-ModulatedRadiotherapy Planning, Computer-AssistedCerenkovDeconvolutionEBRTexternal beam radiotherapyIMRTintensity modulated radiotherapymolecular imagingtomography

Identifiers

PMID30980725
PMCPMC7189122

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.