Evidence map›Paper›PMID 30979911›Full record

ArticleScientific reports2019

Metric-guided regularisation parameter selection for statistical iterative reconstruction in computed tomography.

Sebastian Allner, Alex Gustschin, Andreas Fehringer, Peter B Noël, Franz Pfeiffer

Abstract read
In one paragraph

Article in Scientific reports, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Sebastian AllnerChair of Biomedical Physics and Department of Physics and Munich School of BioEngineering, Technical University of Munich, 85748, Garching, Germany. Sebastian.Allner@tum.de.
Alex GustschinChair of Biomedical Physics and Department of Physics and Munich School of BioEngineering, Technical University of Munich, 85748, Garching, Germany.ORCID http://orcid.org/0000-0002-1559-5495
Andreas FehringerMITOS GmbH, 85748, Garching, Germany.
Peter B NoëlDepartment of Diagnostic and Interventional Radiology, Klinikum rechts der Isar, Technical University of Munich, 81675, München, Germany.
Franz PfeifferChair of Biomedical Physics and Department of Physics and Munich School of BioEngineering, Technical University of Munich, 85748, Garching, Germany.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

As iterative reconstruction in Computed Tomography (CT) is an ill-posed problem, additional prior information has to be used to get a physically meaningful result (close to ground truth if available). However, the amount of influence of the regularisation prior is crucial to the outcome of the reconstruction. Therefore, we propose a scheme for tuning the strength of the prior via a certain image metric. In this work, the parameter is tuned for minimal histogram entropy in selected regions of the reconstruction as histogram entropy is a very basic approach to characterise the information content of data. We performed a sweep over different regularisation parameters showing that the histogram entropy is a suitable metric as it is well behaved over a wide range of parameters. The parameter determination is a feedback loop approach we applied to numerically simulated FORBILD phantom data and verified with an experimental measurement of a micro-CT device. The outcome is evaluated visually and quantitatively by means of root mean squared error (RMSE) and structural similarity (SSIM) for the simulation and visually for the measured sample (no ground truth available). The final reconstructed images exhibit noise-suppressed iterative reconstruction. For both datasets, the optimisation is robust where its initial value is concerned. The parameter tuning approach shows that the proposed metric-driven feedback loop is a promising tool for finding a suitable regularisation parameter in statistical iterative reconstruction.

Identifiers

PMID30979911
PMCPMC6461679

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.