Evidence map›Paper›PMID 30976208›Full record

ArticleIEEE transactions on robotics : a publication of the IEEE Robotics and Automation Society2019

Modeling Tube Clearance and Bounding the Effect of Friction in Concentric Tube Robot Kinematics.

Junhyoung Ha, Georgios Fagogenis, Pierre E Dupont

Abstract read
In one paragraph

Article in IEEE transactions on robotics : a publication of the IEEE Robotics and Automation Society, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 10 papers.

0numbers the graph read from it
0cells of the map it votes in
10citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

10 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Continuum Robots for Medical Interventions.Proceedings of the IEEE. Institute of Electrical and Electronics Engineers · 2022
    Article
  6. Eccentric Tube Robots as Multiarmed Steerable Sheaths.IEEE transactions on robotics : a publication of the IEEE Robotics and Automation Society · 2022
    Article
  7. Article
  8. Article
  9. A Dynamic Model for Concentric Tube Robots.IEEE transactions on robotics : a publication of the IEEE Robotics and Automation Society · 2020
    Article
  10. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Junhyoung HaDepartment of Cardiovascular Surgery, Boston Children's Hospital, Harvard Medical School, Boston, MA 02115 USA.ORCID 0000-0002-6568-4154
Georgios FagogenisDepartment of Cardiovascular Surgery, Boston Children's Hospital, Harvard Medical School, Boston, MA 02115 USA.
Pierre E DupontDepartment of Cardiovascular Surgery, Boston Children's Hospital, Harvard Medical School, Boston, MA 02115 USA.ORCID 0000-0001-7294-640X

Funding

Cardioscopically-guided Valve Repair in the Beating HeartR01HL124020 · NHLBI · BOSTON CHILDREN'S HOSPITAL · PI Pierre E Dupont · 2014 to 2026
$9.7M
NHLBI NIH HHS R01 HL124020
6 · The paper itself

Abstract

The shape of a concentric tube robot depends not only on the relative rotations and translations of its constituent tubes, but also on the history of relative tube displacements. Existing mechanics-based models neglect all history-dependent phenomena with the result that when calibrated on experimental data collected over a robot's workspace, the maximum tip position error can exceed 8 mm for a 200-mm-long robot. In this paper, we develop a model that computes the bounding kinematic solutions in which Coulomb friction is acting either to maximize or minimize the relative twisting between each pair of contacting tubes. The path histories associated with these limiting cases correspond to first performing all tube translations and then performing relative tube rotations of sufficient angle so that the maximum Coulomb friction force is obtained along the interface of each contacting tube pair. The robot tip configurations produced by these path histories are shown experimentally to bound position error with respect to the estimated frictionless model compared to path histories comprised of translation or mixed translation and rotation. Intertube friction forces and torques are computed as proportional to the intertube contact forces. To compute these contact forces, the standard zero-clearance assumption that constrains the concentrically combined tubes to possess the same centerline is relaxed. The effects of clearance and friction are explored through numerical and physical experiments and it is shown that friction can explain much of the prediction error observed in existing models. This model is not intended for real-time control, but rather for path planning-to provide error bounds and to inform how the ordering of tube rotations and translations can be used to reduce the effect of friction.

Indexed as

Concentric tube robotsfrictionmodel calibrationtube clearance

Identifiers

PMID30976208
PMCPMC6453576

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.