ArticleJournal of diabetes science and technology2019

Laboratory Evaluation of Linearity, Repeatability, and Hematocrit Interference With an Internet-Enabled Blood Glucose Meter.

Filiz Demircik, Valeria Kirsch, Sanja Ramljak, Mario Vogg, Anke H Pfützner, Andreas Pfützner

Abstract readEvaluation Study
In one paragraph

Article in Journal of diabetes science and technology, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

6 authors.

Filiz Demircik1 Pfützner Science & Health Institute, Germany.
Valeria Kirsch1 Pfützner Science & Health Institute, Germany.
Sanja Ramljak2 Sciema-Science & Marketing UG, Mainz, Germany.
Mario Vogg4 Technical University, Bingen, Germany.
Anke H Pfützner2 Sciema-Science & Marketing UG, Mainz, Germany.
Andreas Pfützner1 Pfützner Science & Health Institute, Germany.ORCID 0000-0003-2385-0887

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundIn recent clinical trials, use of the MyGlucoHealth blood glucose meter (BGM) and electronic diary was associated with an unusual reporting pattern of glycemic data and hypoglycemic events. Therefore, the performance of representative BGMs used by the patients was investigated to assess repeatability, linearity, and hematocrit interference in accordance with regulatory guidelines.

methodTen devices and 6 strip lots were selected using standard randomization and repeatability procedures. Venous heparinized blood was drawn from healthy subjects, immediately aliquoted and adjusted to 5 target blood glucose (BG) ranges for the repeatability and 11 BG concentrations for the linearity tests. For the hematocrit interference test, each sample within 5 target BG ranges was split into 5 aliquots and adjusted to hematocrit levels across the acceptance range. YSI 2300 STAT Plus was used as the laboratory reference method in all experiments.

resultsMeasurement repeatability or precision was acceptable across the target BG ranges for all devices and strip lots with coefficient of variation (CV) between 3.4-9.7% (mean: 5.7%). Linearity was shown by a correlation coefficient of .991; however, a positive bias was seen for BG <100 mg/dL (86% measurements did not meet ISO15197:2015 acceptance criteria). Significant hematocrit interference (up to 20%) was observed for BG >100 mg/dL (ISO15197:2015 acceptance criteria: ±10%), while the results were acceptable for BG <100 mg/dL.

conclusionsThe BGM met repeatability requirements but demonstrated a significant measurement bias in the low BG range. In addition, it failed the ISO15197:2015 criteria for hematocrit interference.

Indexed as

Clinical Laboratory TechniquesInternet AccessArtifactsBlood GlucoseBlood Glucose Self-MonitoringDiabetes MellitusEquipment and SuppliesEquipment DesignEquipment Failure AnalysisHematocritHumansLinear ModelsReagent StripsReproducibility of ResultsBlood GlucoseReagent Stripsblood glucose meterhematocrit interferencelinearityrepeatability

Identifiers

PMID30974988
PMCPMC6501519

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.