ArticleSensors (Basel, Switzerland)2019
Characterization of Gas Absorption Modules Based on Flexible Mid-Infrared Hollow Waveguides.
Article in Sensors (Basel, Switzerland), 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
- CHSensors (Basel, Switzerland) · 2023Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
A new gas absorption module, the substrate-embedded hollow waveguide (eHWG) model, is proposed. It consists of a substrate with a curved channel and a hollow waveguide. The hollow waveguide is curved into the channel and works as a gas absorption cell as well as a transmission medium for mid-infrared light. Owing to the low loss property of the hollow waveguide, the signal-to-noise ratio (SNR) was improved for the sensing system. A polycarbonate (PC) base tube was used to obtain flexibility in the fabrication of the hollow waveguide. A silver (Ag) layer and a silver iodide (AgI) layer were inner-coated to ensure a low loss property at the fingerprint wavelength of methane gas. A sensing system was established using a Fourier transform infrared spectrometer (FTIR), an external detector, and an eHWG. Experimental investigations were carried on the sensing performance of eHWGs with various channel shapes. Comparison studies were made on eHWGs embedded with Ag-coated or Ag- and AgI-coated hollow waveguides. The Ag- and AgI-coated hollow waveguides with inner diameters of 0.7, 1.4, and 2.0 mm were used in the eHWGs. The large bore waveguide had low loss but high bending additional loss. The large bore waveguide had a low detection limit due to high coupling efficiency with the light source. A limit of detection (LOD) as low as 2.7 ppm was attained for the system using the eHWG with the long and large bore waveguide.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.