Evidence map›Paper›PMID 30974505›Full record

ReviewJournal of applied microbiology2019

Collection, particle sizing and detection of airborne viruses.

M Pan, J A Lednicky, C-Y Wu

Abstract readReview
In one paragraph

Review in Journal of applied microbiology, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 112 papers, 2 of them syntheses that pooled it.

0numbers the graph read from it
0cells of the map it votes in
112citing papers in PubMed, 2 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

112 citing papers in PubMed, 2 syntheses or guidelines pooled it.

  1. Pooled it
  2. SARS-CoV-2: a systematic review of indoor air sampling for virus detection.Environmental science and pollution research international · 2021
    Pooled it
  3. Article
  4. Article
  5. Article
  6. Article
  7. Development of a Platform forAerosol science and technology : the journal of the American Association for Aerosol Research · 2026
    Article
  8. Article
  9. Review
  10. Article
  11. Article
  12. Article
  13. Article
  14. Article
  15. Article
  16. Review
  17. Review
  18. Article
  19. Article
  20. Occupational exposure monitoring of airborne respiratory viruses in outpatient medical clinics.Aerosol science and technology : the journal of the American Association for Aerosol Research · 2024
    Article

52 more citing papers are in PubMed but not listed here.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

M PanDepartment of Environmental Engineering Sciences, Engineering School of Sustainable Infrastructure and Environment, University of Florida, Gainesville, FL, USA.
J A LednickyDepartment of Environmental and Global Health, College of Public Health & Health Professions, University of Florida, Gainesville, FL, USA.ORCID https://orcid.org/0000-0003-4069-0539
C-Y WuDepartment of Environmental Engineering Sciences, Engineering School of Sustainable Infrastructure and Environment, University of Florida, Gainesville, FL, USA.ORCID https://orcid.org/0000-0002-2100-8816

Funding

National Science Foundation IDBR-1353423
6 · The paper itself

Abstract

Viruses that affect humans, animals and plants are often dispersed and transmitted through airborne routes of infection. Due to current technological deficiencies, accurate determination of the presence of airborne viruses is challenging. This shortcoming limits our ability to evaluate the actual threat arising from inhalation or other relevant contact with aerosolized viruses. To improve our understanding of the mechanisms of airborne transmission of viruses, air sampling technologies that can detect the presence of aerosolized viruses, effectively collect them and maintain their viability, and determine their distribution in aerosol particles, are needed. The latest developments in sampling and detection methodologies for airborne viruses, their limitations, factors that can affect their performance and current research needs, are discussed in this review. Much more work is needed on the establishment of standard air sampling methods and their performance requirements. Sampling devices that can collect a wide size range of virus-containing aerosols and maintain the viability of the collected viruses are needed. Ideally, the devices would be portable and technology-enabled for on-the-spot detection and rapid identification of the viruses. Broad understanding of the airborne transmission of viruses is of seminal importance for the establishment of better infection control strategies.

Indexed as

Air MicrobiologySpecimen HandlingAerosolsAir PollutantsAnimalsHumansParticle SizeVirusesAerosolsAir Pollutantsaerosolaerovirologyairborne transmissionair samplercollection efficiencysize distribution

Identifiers

PMID30974505
PMCPMC7167052

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.