Evidence map›Paper›PMID 30971307›Full record

ArticleCritical care (London, England)2019

What is the lowest change in cardiac output that transthoracic echocardiography can detect?

Mathieu Jozwiak, Pablo Mercado, Jean-Louis Teboul, Anouar Benmalek, Julia Gimenez, François Dépret, Christian Richard, Xavier Monnet

2 registry-linked trialsOpen access · goldAbstract read
In one paragraph

Article in Critical care (London, England), 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to 2 registered trials, which are not on this map. Cited by 90 papers, 2 of them syntheses that pooled it.

0numbers the graph read from it
0cells of the map it votes in
90citing papers in PubMed, 2 pooled it
15.7field-weighted citation impact, top 1% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

NCT05211765 unknown statusnot on this mapstarted 2021, after this paper: background citation

Association of Respiratory Variation of Superior Vena Cava in Transthoracic View and Fluid Responsiveness in Critically Ill Patients

TypeobservationalSponsorUniversity of ChileRan2021 to 2024Enrolled100ConditionsShockArmsSuperior vena cava transthoracic evaluation
NCT06486467 narecruitingnot on this mapstarted 2024, after this paper: background citation

Reliability of Minimally Trained Operator's Velocity-Time Integral Measurement Guided by Artificial Intelligence (MiniTrained-VTI)

TypeinterventionalSponsorAssistance Publique - Hôpitaux de ParisRan2024 to 2026Enrolled100ConditionsVelocity-time Integral Measurement, Critically Ill Patients, Tissue HypoperfusionArmsFluid challenge (cristalloids) OR passive leg raising
3 · Its place in the literature

Who cites it

90 citing papers in PubMed, 2 syntheses or guidelines pooled it, 172 citations in OpenAlex.

  1. Guideline
  2. Pooled it
  3. Trial
  4. Trial
  5. Trial
  6. Article
  7. Article
  8. Article
  9. Article
  10. Review
  11. Review
  12. Observational
  13. Review
  14. Article
  15. Article
  16. Article
  17. Article
  18. Observational
  19. Article
  20. Changes in COJournal of clinical medicine · 2026
    Article

30 more citing papers are in PubMed but not listed here.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 2 institutions in 1 country.

Mathieu JozwiakHôpitaux Universitaires Paris-Sud, Hôpital de Bicêtre, APHP, Service de Médecine Intensive-Réanimation et de Surveillance Continue Médicale, 78, rue du Général Leclerc, F-94270, Le Kremlin-Bicêtre, France. mathieu.jozwiak@aphp.fr.ORCID http://orcid.org/0000-0003-3379-4065
Pablo MercadoHôpitaux Universitaires Paris-Sud, Hôpital de Bicêtre, APHP, Service de Médecine Intensive-Réanimation et de Surveillance Continue Médicale, 78, rue du Général Leclerc, F-94270, Le Kremlin-Bicêtre, France.
Jean-Louis TeboulHôpitaux Universitaires Paris-Sud, Hôpital de Bicêtre, APHP, Service de Médecine Intensive-Réanimation et de Surveillance Continue Médicale, 78, rue du Général Leclerc, F-94270, Le Kremlin-Bicêtre, France.
Anouar BenmalekFaculté de Pharmacie, Université Paris-Sud, 5 rue Jean-Baptiste Clément, F-92290, Châtenay-Malabry, France.
Julia GimenezHôpitaux Universitaires Paris-Sud, Hôpital de Bicêtre, APHP, Service de Médecine Intensive-Réanimation et de Surveillance Continue Médicale, 78, rue du Général Leclerc, F-94270, Le Kremlin-Bicêtre, France.
François DépretHôpitaux Universitaires Paris-Sud, Hôpital de Bicêtre, APHP, Service de Médecine Intensive-Réanimation et de Surveillance Continue Médicale, 78, rue du Général Leclerc, F-94270, Le Kremlin-Bicêtre, France.
Christian RichardHôpitaux Universitaires Paris-Sud, Hôpital de Bicêtre, APHP, Service de Médecine Intensive-Réanimation et de Surveillance Continue Médicale, 78, rue du Général Leclerc, F-94270, Le Kremlin-Bicêtre, France.
Xavier MonnetHôpitaux Universitaires Paris-Sud, Hôpital de Bicêtre, APHP, Service de Médecine Intensive-Réanimation et de Surveillance Continue Médicale, 78, rue du Général Leclerc, F-94270, Le Kremlin-Bicêtre, France.
Inserm · FRUniversité Paris-Sud · FR

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundIn critically ill patients, changes in the velocity-time integral (VTI) of the left ventricular outflow tract, measured by transthoracic echocardiography (TTE), are often used to non-invasively assess the response to fluid administration or for performing tests assessing fluid responsiveness. However, the precision of TTE measurements has not yet been investigated in such patients. First, we aimed at assessing how many measurements should be averaged within one TTE examination to reach a sufficient precision for various variables. Second, we aimed at identifying the least significant change (LSC) of these variables between successive TTE examinations.

methodsWe prospectively included 100 haemodynamically stable patients in whom TTE examination was planned. Three TTE examinations were performed, the first and the third by one operator and the second by another one. We calculated the precision and LSC (1) within one examination depending on the number of averaged measurements and (2) between measurements performed in two successive examinations.

resultsIn patients in sinus rhythm, averaging three measurements within an examination was enough for obtaining an acceptable precision (interquartile range highest value < 10%) for VTI. In patients with atrial fibrillation, averaging five measurements was necessary. The precision of some other common TTE variables depending on the number of measurements is provided. Between two successive examinations performed by the same operator, the LSC was 11 [5-18]% for VTI. If two operators performed the examinations, the LSC for VTI significantly increased to 14 [8-26]%. The LSC between two examinations for other TTE variables is also provided.

conclusionsAveraging three measurements within one TTE examination is enough for obtaining precise measurements for VTI in patients in sinus rhythm but not in patients with atrial fibrillation. Between two TTE examinations performed by the same operator, the LSC of VTI is compatible with the assessment of the effects of a 500-mL fluid infusion but is not precise enough for assessing the effects of some tests predicting preload responsiveness.

Indexed as

AgedAged, 80 and overCardiac OutputCritical IllnessEchocardiographyFemaleFluid TherapyFranceHumansIntensive Care UnitsMaleMiddle AgedProspective StudiesReproducibility of ResultsStroke VolumeWeights and MeasuresFluid challengeFluid responsivenessIntensive care unitUltrasoundVelocity-time integral

Identifiers

PMID30971307
PMCPMC6458708
OpenAlexW2944929594

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.