Evidence map›Paper›PMID 30967747›Full record

ArticleClinical Medicine Insights. Cardiology2019

Impact of Cine Frame Selection on Quantitative Coronary Angiography Results.

Shigenori Ito, Kanako Kinoshita, Akiko Endo, Masato Nakamura

Abstract read
In one paragraph

Article in Clinical Medicine Insights. Cardiology, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed.

  1. Trial
  2. Article
  3. Review
  4. Article
  5. Article
  6. Review
  7. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Shigenori ItoJapan Cardiovascular Imaging Core Laboratory, Tokyo, Japan.ORCID https://orcid.org/0000-0002-3319-1697
Kanako KinoshitaJapan Cardiovascular Imaging Core Laboratory, Tokyo, Japan.
Akiko EndoJapan Cardiovascular Imaging Core Laboratory, Tokyo, Japan.
Masato NakamuraJapan Cardiovascular Imaging Core Laboratory, Tokyo, Japan.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

We evaluated intra- and interobserver variability of quantitative coronary angiography (QCA) due to cine frame selection for 9 coronary stenoses. The projection was selected in advance. Cine frames were selected by 2 blinded experts (blind frame QCA) followed by assignment by supervisor (pre-selected frame QCA). Each expert analyzed 18 frames twice with a 3-month interval. A total of 72 measurements by 2 experts were used for intra- and interobserver variability analysis in calibration factor (CF), minimal lumen diameter (MLD), percent diameter stenosis (%DS), interpolated reference diameter (Int R), and lesion length (LL). Accuracy, precision, and coefficient of variation (CV) were calculated based on 2 measurements. For interobserver variability, intraclass correlation coefficient (ICC) was evaluated. Regarding intraobserver variability, precision (CV) was 0.0026 (1.45), 0.220 (25.1), 0.282 (11.0), 7.626 (11.8), and 4.042 (28.7) for blind frame QCA and 0.0044 (2.46), 0.094 (11.2), 0.225 (8.6), 3.924 (5.9), and 1.941 (12.1) for pre-selected frame QCA and regarding interobserver variability, precision (CV) was 0.0037 (2.09), 0.271 (31.8), 0.307 (11.9), 10.10 (15.4), and 5.121 (39.5) for blind frame QCA and 0.0050 (2.82), 0.098 (11.4), 0.246 (9.5), 5.253 (8.0), and 2.857 (19.0) for pre-selected frame QCA in CF, MLD, Int R, %DS, and LL, respectively. Intraclass correlation coefficient of Int R was almost perfect in blind and pre-selected frame QCA. Intraclass correlation coefficient of MLD, %DS, and LL were substantial/lower by blind frame QCA and improved to almost perfect by pre-selected frame QCA. Blind cine film selection might affect intra- and interobserver variability, especially in MLD and LL. In the multiple linear regression analysis, blind frame QCA was selected as an explanatory factor of QCA variability in MLD, %DS, and LL. The error range due to frame selection must be taken into consideration in clinical use.

Indexed as

cardiac cyclecore laboratorycoronary interventioncoronary stenosisframe selectionminimal lumen diameterquantitative coronary angiography

Identifiers

PMID30967747
PMCPMC6444776

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.