ArticleMedical & biological engineering & computing2019
Using a numerical method to precisely evaluate the alpha angle in a hip image.
Article in Medical & biological engineering & computing, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors.
Funding
Abstract
The alpha angle is a parameter extensively used to assess for cam-type femoroacetabular impingement (FAI) in a 2D image of the hip. As this angle requires estimation of the axis of the femoral neck, the drawing of this axis often results in measurement errors due to subjective judgment, influencing inter-rater and intra-rater agreements. In the present study, sampling points were captured from the edges of a femoral neck and head in the 2D image, and the best curves of the two were fitted respectively by using the curve fitting method. The morphology of the femoral neck was outlined by two polynomials, and the femoral head was represented by an equation of a circle. By means of the proposed method, the results reveal that the inter-rater ICCs in X-ray and MRI were respectively 0.905 and 0.969, and the intra-rater ICCs in X-ray and MRI were respectively 0.892 and 0.840. The Bland-Altman plot shows that the values obtained by the proposed method and the conventional method were not consistent; nevertheless, the linear regression analysis indicated the two measurement results had a significant association (p < 0.001). This study provides a repeatable and agreed α angle measuring method, which contributes to identifying normal and abnormal femoral head-neck morphologies. The proposed numerical method would contribute to diagnose early FAI.
Indexed as
Identifiers
30963390What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.