Investigation of TLD and EBT3 performance under the presence of 1.5T, 0.35T, and 0T magnetic field strengths in MR/CT visible materials.

A Steinmann, D O'Brien, R Stafford, G Sawakuchi, Z Wen, L Court, C Fuller, D Followill

Abstract read
In one paragraph

Article in Medical physics, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 10 papers.

0numbers the graph read from it
0cells of the map it votes in
10citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

10 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Review
  8. Article
  9. Medical physics challenges in clinical MR-guided radiotherapy.Radiation oncology (London, England) · 2020
    Review
  10. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

A SteinmannDepartment of Radiation Physics, The University of Texas M.D. Anderson Cancer Center, Houston, TX, 77030, USA.
D O'BrienDepartment of Radiation Physics, The University of Texas M.D. Anderson Cancer Center, Houston, TX, 77030, USA.
R StaffordDepartment of Imaging Physics, The University of Texas M.D. Anderson Cancer Center, Houston, TX, 77030, USA.
G SawakuchiDepartment of Radiation Physics, The University of Texas M.D. Anderson Cancer Center, Houston, TX, 77030, USA.
Z WenDepartment of Radiation Physics, The University of Texas M.D. Anderson Cancer Center, Houston, TX, 77030, USA.
L CourtDepartment of Radiation Physics, The University of Texas M.D. Anderson Cancer Center, Houston, TX, 77030, USA.
C FullerDepartment of Radiation Oncology, The University of Texas M.D. Anderson Cancer Center, Houston, TX, 770304, USA.
D FollowillDepartment of Radiation Physics, The University of Texas M.D. Anderson Cancer Center, Houston, TX, 77030, USA.

Funding

IROC: Enhancing local enrolling site radiological data capture capabilities for NCTN trialsU24CA180803 · NCI · AMERICAN COLLEGE OF RADIOLOGY · PI Thomas J. FitzGerald, MICHAEL V KNOPP · 2014 to 2026
$116.2M
Andrew Sabin Family FoundationNCI NIH HHS U24 CA180803United States Department of Health and Human Services
6 · The paper itself

Abstract

purposeThe aim of this study was to investigate thermoluminescent dosimeters (TLD) and radiochromic EBT3 film inside MR/CT visible geometric head and thorax phantoms in the presence of: 0, 0.35, and 1.5 T magnetic fields.

methodsThermoluminescent Dosimeters reproducibility studies were examined by irradiating IROC-Houston's TLD acrylic block five times under 0 and 1.5 T configurations of Elekta's Unity system and three times under 0 and 0.35 T configurations of ViewRay's MRIdian Cobalt-60 (

resultsAverage TLD block measurements which, compared the magnetic field effects (magnetic field vs 0 T) on the Unity and MRIdian systems, were 0.5% and 0.6%, respectively. The average ratios between magnetic field effects for the geometric thorax and head phantoms under the Unity system were -0.2% and 1.6% and for the MRIdian system were 0.2% and -0.3%, respectively. Beam profiles generated with both systems agreed with Monte Carlo measurements and previous literature findings.

conclusionsTLDs and EBT3 film dosimeters could potentially be used in MR/CT visible tissue equivalent phantoms that will experience a magnetic field environment.

Indexed as

Magnetic FieldsMagnetic Resonance ImagingTomography, X-Ray ComputedFilm DosimetryMonte Carlo MethodPhantoms, ImagingThermoluminescent Dosimetrydosimeters in magnetic fieldsMRgRTMRgRT dosimetersMRIgRTMR linac

Identifiers

PMID30950071
PMCPMC9673483

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.