Evidence map›Paper›PMID 30946877›Full record

ArticleJournal of neuroscience methods2019

A Teensy microcontroller-based interface for optical imaging camera control during behavioral experiments.

Michael Romano, Mark Bucklin, Howard Gritton, Dev Mehrotra, Robb Kessel, Xue Han

Open access · greenAbstract read
In one paragraph

Article in Journal of neuroscience methods, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
0.1field-weighted citation impact, top 57% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 8 citations in OpenAlex.

  1. Article
  2. Article
  3. The autism spectrum disorder risk geneFrontiers in neuroscience · 2023
    Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 1 institution in 1 country.

Michael RomanoBoston University, Department of Biomedical Engineering, Boston, MA 02215, United States.
Mark BucklinBoston University, Department of Biomedical Engineering, Boston, MA 02215, United States.
Howard GrittonBoston University, Department of Biomedical Engineering, Boston, MA 02215, United States.
Dev MehrotraBoston University, Department of Biomedical Engineering, Boston, MA 02215, United States.
Robb KesselBoston University, Department of Biomedical Engineering, Boston, MA 02215, United States.
Xue HanBoston University, Department of Biomedical Engineering, Boston, MA 02215, United States. Electronic address: xiahd@iet.cn.
Boston University · US

Funding

Unveiling the mechanisms of ultrasound neuromodulation via spatially confined stimulation and temporally resolved recordingR01NS109794 · NINDS · BOSTON UNIVERSITY (CHARLES RIVER CAMPUS) · PI CHENG, JI-XIN, HAN, XUE · 2018 to 2022
$3.6M
Light-Actuatable NanoRobots for Molecular UncagingDP2NS082126 · NINDS · BOSTON UNIVERSITY (CHARLES RIVER CAMPUS) · PI HAN, XUE · 2012 to 2017
$2.9M
NINDS NIH HHS DP2 NS082126NINDS NIH HHS R01 NS109794
6 · The paper itself

Abstract

backgroundSystems neuroscience experiments often require the integration of precisely timed data acquisition and behavioral monitoring. While specialized commercial systems have been designed to meet various needs of data acquisition and device control, they often fail to offer flexibility to interface with new instruments and variable behavioral experimental designs. NEW

methodWe developed a Teensy 3.2 microcontroller-based interface that is easily programmable, and offers high-speed, precisely timed behavioral data acquisition and digital and analog outputs for controlling sCMOS cameras and other devices.

resultsWe demonstrate the flexibility and the temporal precision of the Teensy interface in two experimental settings. In one example, we used the Teensy interface to record an animal's directional movement on a spherical treadmill, while delivering repeated digital pulses that can be used to control image acquisition from a sCMOS camera. In another example, we used the Teensy interface to deliver an auditory stimulus and a gentle eye puff at precise times in a trace conditioning eye blink behavioral paradigm, while delivering repeated digital pulses to trigger camera image acquisition. COMPARISON WITH EXISTING

methodsThis interface allows high-speed and temporally precise digital data acquisition and device control during diverse behavioral experiments.

conclusionThe Teensy interface, consisting of a Teensy 3.2 and custom software functions, provides a temporally precise, low-cost, and flexible platform to integrate sCMOS camera control into behavioral experiments.

Indexed as

AnimalsBehavioral ResearchBehavior, AnimalFemaleMiceMice, Inbred C57BLNeurosciencesOptical ImagingADNS-9800 gaming sensorArduinoMicrocontrollerOpen-sourcesCMOS cameraSpherical treadmillTeensy

Identifiers

PMID30946877
PMCPMC6510265
OpenAlexW2914368685

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.