ArticleEuropean radiology experimental2019
Timing optimization of low-dose first-pass analysis dynamic CT myocardial perfusion measurement: validation in a swine model.
Article in European radiology experimental, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 17 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
17 citing papers in PubMed.
- Patient-Specific Timing for Pulmonary CT Angiography: Human Validation of a Physiologically Derived Post-Trigger Delay Model.Diagnostics (Basel, Switzerland) · 2026Article
- Patient-specific timing acquisition for coronary CT angiography: A retrospective patient validation study.European journal of radiology open · 2026Article
- Sinogram-based flow estimation in computed tomography using a physics-informed neural network: Impact of gantry rotation speed, X-ray fluence and pulsed acquisition on accuracy.Medical physics · 2026Article
- Quantifying lower extremity blood flow using low-dose CT perfusion: validation in a swine model.Radiology advances · 2024Article
- Reproducibility of a single-volume dynamic CT myocardial blood flow measurement technique: validation in a swine model.European radiology experimental · 2024Article
- A patient-specific timing protocol for improved CT pulmonary angiography.Research in diagnostic and interventional imaging · 2023Article
- Low-dose quantitative CT myocardial flow measurement using a single volume scan: phantom and animal validation.Journal of medical imaging (Bellingham, Wash.) · 2023Article
- Evaluation and timing optimization of CT perfusion first pass analysis in comparison to maximum slope model in pancreatic adenocarcinoma.Scientific reports · 2023Article
- Computation of contrast-enhanced perfusion using only two CT scan phases: a proof-of-concept study on abdominal organs.European radiology experimental · 2022Article
- Dynamic CT myocardial perfusion without image registration.Scientific reports · 2022Article
- Absolute cerebral blood flow: Assessment with a novel low-radiation-dose dynamic CT perfusion technique in a swine model.Journal of neuroradiology = Journal de neuroradiologie · 2022Article
- Combining computed tomography and biologically effective dose in radiomics and deep learning improves prediction of tumor response to robotic lung stereotactic body radiation therapy.Medical physics · 2021Article
- Combining perfusion and angiography with a low-dose cardiac CT technique: a preliminary investigation in a swine model.The international journal of cardiovascular imaging · 2021Article
- At the heart of innovation: cardiac imaging in 2019.European radiology · 2021Article
- Computed tomography for myocardial characterization in ischemic heart disease: a state-of-the-art review.European radiology experimental · 2020Review
- Dynamic pulmonary CT perfusion using first-pass analysis technique with only two volume scans: Validation in a swine model.PloS one · 2020Article
- Low-Radiation-Dose Stress Myocardial Perfusion Measurement Using First-Pass Analysis Dynamic Computed Tomography: A Preliminary Investigation in a Swine Model.Investigative radiology · 2019Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors.
Funding
Abstract
backgroundMyocardial perfusion measurement with a low-dose first-pass analysis (FPA) dynamic computed tomography (CT) perfusion technique depends upon acquisition of two whole-heart volume scans at the base and peak of the aortic enhancement. Hence, the objective of this study was to validate an optimal timing protocol for volume scan acquisition at the base and peak of the aortic enhancement.
methodsContrast-enhanced CT of 28 Yorkshire swine (weight, 55 ± 24 kg, mean ± standard deviation) was performed under rest and stress conditions over 20-30 s to capture the aortic enhancement curves. From these curves, an optimal timing protocol was simulated, where one volume scan was acquired at the base of the aortic enhancement while a second volume scan was acquired at the peak of the aortic enhancement. Low-dose FPA perfusion measurements (P
resultsP
conclusionsAn optimal timing protocol for volume scan acquisition at the base and peak of the aortic enhancement was retrospectively validated and has the potential to be used to implement an accurate, low-dose, FPA perfusion technique.