Evidence map›Paper›PMID 30945044›Full record

ArticleIntensive care medicine experimental2019

Comparison of aerosol delivery across combinations of drug delivery interfaces with and without concurrent high-flow nasal therapy.

Gavin Bennett, Mary Joyce, Elena Fernández Fernández, Ronan MacLoughlin

Open access · goldAbstract read
In one paragraph

Article in Intensive care medicine experimental, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 20 papers.

0numbers the graph read from it
0cells of the map it votes in
20citing papers in PubMed
4.4field-weighted citation impact, top 5% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

20 citing papers in PubMed, 37 citations in OpenAlex.

  1. Article
  2. Short-acting βInternal medicine (Tokyo, Japan) · 2025
    Article
  3. Review
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Review
  10. Article
  11. Article
  12. Cellular Therapy for the Treatment of Paediatric Respiratory Disease.International journal of molecular sciences · 2021
    Review
  13. Demystifying medical aerosols in acute and critical care.Annals of translational medicine · 2021
    Article
  14. Review
  15. Review
  16. Review
  17. Review
  18. Article
  19. Article
  20. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 1 institution in 1 country.

Gavin BennettAerogen Limited, IDA Business Park, Dangan, Galway, Ireland. GBennett@aerogen.com.ORCID http://orcid.org/0000-0002-1914-953X
Mary JoyceAerogen Limited, IDA Business Park, Dangan, Galway, Ireland.
Elena Fernández FernándezAerogen Limited, IDA Business Park, Dangan, Galway, Ireland.
Ronan MacLoughlinAerogen Limited, IDA Business Park, Dangan, Galway, Ireland.
Aerogen (Ireland) · IE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundCurrent clinical practice during high-flow nasal therapy (HFNT) involves utilization of a nasal cannula to provide humidification, with a facemask placed over the cannula to deliver aerosol. Few studies have compared aerosol delivery across various delivery interfaces during HFNT. The objective of this study was to address this gap in the literature and evaluate aerosol delivery using two nebulizer types across different drug delivery interfaces, nasal cannula, facemask, and mouthpiece, during simulated adult HFNT.

methodsA facemask or mouthpiece and/or a nasal cannula were positioned on an anatomically correct adult head model. The head model was connected to a breathing simulator via a collection filter. Both healthy breathing pattern and distressed breathing patterns were utilized. Aerosol dose was determined by quantifying the mass of drug captured on a filter positioned distal to the trachea.

resultsDuring simulated healthy breathing, a significantly greater aerosol dose was observed when the vibrating mesh nebulizer (VMN) was integrated with HFNT alone, supplying aerosol and humidified air simultaneously (2.88 ± 0.15%), as opposed to using with a facemask (0.33 ± 0.07%, 1.62 ± 0.46%, and 1.07 ± 0.25% at 0 L/min (LPM), 2LPM, and 6LPM, respectively) or mouthpiece (0.56 ± 0.13%, 2.16 ± 0.06%, and 1.82 ± 0.41% at 0LPM, 2LPM, and 6LPM). In addition, aerosol delivery was also significantly greater when the VMN was integrated into simulated HFNT (2.88 ± 0.15%), in comparison with using the jet nebulizer (JN) with a facemask (0.82 ± 0.16%) or a mouthpiece (0.86 ± 0.11%). During simulated distressed breathing, a significantly greater aerosol dose was observed when the VMN was integrated with HFNT, supplying aerosol and humidified air simultaneously (6.81 ± 0.45%), compared with using a facemask (0.86 ± 0.04%, 2.96 ± 0.26%, and 4.23 ± 0.93% at 0LPM, 2LPM, and 6LPM) or mouthpiece (0.73 ± 0.37%, 0.97 ± 0.20%, and 3.11 ± 0.53% at 0LPM, 2LPM, and 6LPM, respectively). Aerosol delivery was also greater when the VMN was integrated into HFNT (6.81 ± 0.45%), in comparison with using the JN with a facemask (5.72 ± 0.71%) or a mouthpiece (0.69 ± 0.53%). Furthermore, across all drug delivery interfaces, and in line with previous reports, aerosol delivery was greater during simulated distressed breathing, in comparison with simulated healthy adult breathing.

conclusionsThis article will be of considerable benefit in enhancing the understanding of aerosol delivery during HFNT, an increasingly adopted therapeutic intervention by healthcare professionals.

Indexed as

AerosolAerosol chamberFacemaskHigh-flow nasal therapyMouthpieceNasal cannulaVibrating mesh nebulizer

Identifiers

PMID30945044
PMCPMC6447636
OpenAlexW2943552828

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked