ArticleScientific reports2019
All-Optical Rotational Ultrasound Imaging.
Article in Scientific reports, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 23 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
23 citing papers in PubMed, 62 citations in OpenAlex.
- A wearable fiber-optoacoustic interface for continuous deep-tissue hemodynamics in MRI environments.Photoacoustics · 2026Article
- Holographic diffusers for endoluminal-scale optical ultrasound imaging.Journal of biomedical optics · 2026Article
- Sustained real-time and video-rate interventional optical ultrasound imaging.Journal of biomedical optics · 2025Article
- Curved Fabry-Pérot Ultrasound Detectors: Optical and Mechanical Analysis.Sensors (Basel, Switzerland) · 2025Article
- Non-iterative model-based inversion for low channel-count optical ultrasound imaginga).The Journal of the Acoustical Society of America · 2024Article
- A fibre-optic ultrasound sensor of simple fabrication.JASA express letters · 2024Article
- Ultrasound sensing with optical microcavities.Light, science & applications · 2024Review
- All-optical ultrasound catheter for rapid B-mode oesophageal imaging.Biomedical optics express · 2023Article
- Miniaturised dual-modality all-optical ultrasound probe for laser interstitial thermal therapy (LITT) monitoring.Biomedical optics express · 2023Article
- Ultrawide-bandwidth high-resolution all-optical intravascular ultrasound using miniaturized photoacoustic transducer.Science advances · 2023Article
- Bend-insensitive fiber optic ultrasonic tracking probe for cardiovascular interventions.Medical physics · 2023Article
- A Comprehensive Review on Photoacoustic-Based Devices for Biomedical Applications.Sensors (Basel, Switzerland) · 2022Review
- A patient-specific multi-modality abdominal aortic aneurysm imaging phantom.International journal of computer assisted radiology and surgery · 2022Article
- Dual-modality fibre optic probe for simultaneous ablation and ultrasound imaging.Communications engineering · 2022Article
- High-resolution sub-millimetre diameter side-viewing all-optical ultrasound transducer based on a single dual-clad optical fibre.Biomedical optics express · 2022Article
- Laser-induced ultrasound transmitters for large-volume ultrasound tomography.Photoacoustics · 2022Article
- Optical ultrasound sensors for photoacoustic imaging: a narrative review.Quantitative imaging in medicine and surgery · 2022Review
- Recent Advancements in Ultrasound Transducer: From Material Strategies to Biomedical Applications.BME frontiers · 2022Review
- Article
- CuInSAdvanced materials interfaces · 2021Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
13 authors at 5 institutions in 1 country.
Funding
Abstract
Miniaturised high-resolution imaging devices are valuable for guiding minimally invasive procedures such as vascular stent placements. Here, we present all-optical rotational B-mode pulse-echo ultrasound imaging. With this device, ultrasound transmission and reception are performed with light. The all-optical transducer in the probe comprised an optical fibre that delivered pulsed excitation light to an optical head at the distal end with a multi-walled carbon nanotube and polydimethylsiloxane composite coating. This coating was photoacoustically excited to generate a highly directional ultrasound beam perpendicular to the optical fibre axis. A concave Fabry-Pérot cavity at the distal end of an optical fibre, which was interrogated with a tuneable continuous-wave laser, served as an omnidirectional ultrasound receiver. The transmitted ultrasound had a -6 dB bandwidth of 31.3 MHz and a peak-to-peak pressure of 1.87 MPa, as measured at 1.5 mm from the probe. The receiver had a noise equivalent pressure <100 Pa over a 20 MHz bandwidth. With a maximum outer probe diameter of 1.25 mm, the probe provided imaging with an axial resolution better than 50 µm, and a real-time imaging rate of 5 frames per second. To investigate the capabilities of the probe, intraluminal imaging was performed in healthy swine carotid arteries. The results demonstrate that the all-optical probe is viable for clinical rotational ultrasound imaging.
Identifiers
What OpenQuestion holds
Registered trials