Evidence map›Paper›PMID 30940359›Full record

ArticleJournal of biomechanics2019

The choice of the femoral center of rotation affects material loss in total knee replacement wear testing - A parametric finite element study of ISO 14243-3.

Steven P Mell, Markus A Wimmer, Hannah J Lundberg

Abstract read
In one paragraph

Article in Journal of biomechanics, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed.

  1. Article
  2. Article
  3. Review
  4. Article
  5. Article
  6. Article
  7. Sensitivity of total knee replacement wear to variability in motion and load input: A parametric finite element analysis study.Journal of orthopaedic research : official publication of the Orthopaedic Research Society · 2020
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Steven P MellRush University Medical Center, Chicago, IL, USA. Electronic address: steven_p_mell@rush.edu.
Markus A WimmerRush University Medical Center, Chicago, IL, USA.
Hannah J LundbergRush University Medical Center, Chicago, IL, USA.

Funding

Wear Testing for Enhanced Prediction of TKR Clinical PerformanceR01AR059843 · NIAMS · RUSH UNIVERSITY MEDICAL CENTER · PI WIMMER, MARKUS ANTON · 2011 to 2014
$1.4M
NIAMS NIH HHS R01 AR059843
6 · The paper itself

Abstract

A leading cause of long-term failure of total knee replacements (TKRs) is osteolysis caused by polyethylene wear particles. The current gold standard for preclinical wear testing of TKRs is mechanical knee simulators. The definition of the femoral center of flexion-extension rotation (CoR) has been identified as one possible source of variability within TKR wear tests, since the femoral curvature varies from distal to posterior. The magnitude of the influence on wear due to changes in location of femoral CoR has not been investigated in depth. During this study, a computational framework utilizing finite element analysis for modelling wear of TKRs was developed and used to investigate the influence of the location of femoral CoR on TKR polyethylene wear during standardized displacement controlled testing (ISO 14243-3:2014). The study was carried out using a 40-point Latin Hypercube Design of Experiments approach. Volumetric wear was highly correlated to femoral CoR in both the superior/inferior and anterior/posterior directions, with a stronger relationship in the superior/inferior direction. In addition, wear scars showing linear penetration were examined, with large differences in simulations at the extreme ends of the sampling region. In this study, it was found that variations in the location of the femoral center of rotation can represent a large source of variability in the preclinical testing and evaluation of the wear performance of total knee replacements. This study represents the first attempt at quantifying the effect on wear of different femoral center of rotations across a large sampling space.

Indexed as

Arthroplasty, Replacement, KneeKnee ProsthesisFemurFinite Element AnalysisHumansKnee JointPolyethyleneProsthesis DesignRotationPolyethyleneComputational modellingFinite element analysisPolyethylene wearTotal knee arthroplasty

Identifiers

PMID30940359
PMCPMC6499703

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.