ArticleJournal of biomechanics2019
The choice of the femoral center of rotation affects material loss in total knee replacement wear testing - A parametric finite element study of ISO 14243-3.
Article in Journal of biomechanics, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
7 citing papers in PubMed.
- Role of relative intentional rotation of the femoral component in robotic-assisted primary total knee arthroplasty as a tool for the correction of medial flexion laxity.Journal of robotic surgery · 2026Article
- Gait-to-Contact (G2C): A Novel Deep Learning Framework to Predict Total Knee Replacement Wear from Gait Patterns.Annals of biomedical engineering · 2026Article
- Biosensor-Integrated Tibial Components in Total Knee Arthroplasty: A Narrative Review of Innovations, Challenges, and Translational Frontiers.Bioengineering (Basel, Switzerland) · 2025Review
- Ankle and subtalar joint axes of rotation and center of rotation during walking and running in healthy individuals measured using dynamic biplane radiography.Journal of biomechanics · 2023Article
- Computational wear of knee implant polyethylene insert surface under continuous dynamic loading and posterior tibial slope variation based on cadaver experiments with comparative verification.BMC musculoskeletal disorders · 2022Article
- Optimal surgical component alignment minimizes TKR wear - An in silico study with nine alignment parameters.Journal of the mechanical behavior of biomedical materials · 2022Article
- Sensitivity of total knee replacement wear to variability in motion and load input: A parametric finite element analysis study.Journal of orthopaedic research : official publication of the Orthopaedic Research Society · 2020Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
3 authors.
Funding
Abstract
A leading cause of long-term failure of total knee replacements (TKRs) is osteolysis caused by polyethylene wear particles. The current gold standard for preclinical wear testing of TKRs is mechanical knee simulators. The definition of the femoral center of flexion-extension rotation (CoR) has been identified as one possible source of variability within TKR wear tests, since the femoral curvature varies from distal to posterior. The magnitude of the influence on wear due to changes in location of femoral CoR has not been investigated in depth. During this study, a computational framework utilizing finite element analysis for modelling wear of TKRs was developed and used to investigate the influence of the location of femoral CoR on TKR polyethylene wear during standardized displacement controlled testing (ISO 14243-3:2014). The study was carried out using a 40-point Latin Hypercube Design of Experiments approach. Volumetric wear was highly correlated to femoral CoR in both the superior/inferior and anterior/posterior directions, with a stronger relationship in the superior/inferior direction. In addition, wear scars showing linear penetration were examined, with large differences in simulations at the extreme ends of the sampling region. In this study, it was found that variations in the location of the femoral center of rotation can represent a large source of variability in the preclinical testing and evaluation of the wear performance of total knee replacements. This study represents the first attempt at quantifying the effect on wear of different femoral center of rotations across a large sampling space.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.