ArticlePhysics in medicine and biology2019
Dynamic fluence field modulation in computed tomography using multiple aperture devices.
Article in Physics in medicine and biology, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
4 citing papers in PubMed, 18 citations in OpenAlex.
- Reconstruction of three-dimensional tomographic patient models for radiation dose modulation in CT from two scout views using deep learning.Medical physics · 2022Article
- Spectral CT using a fine grid structure and varying x-ray incidence angle.Medical physics · 2021Article
- Grating-based Spectral CT using Small Angle X-ray Beam Deflections.Conference proceedings. International Conference on Image Formation in X-Ray Computed Tomography · 2020Article
- Volume-of-interest imaging with dynamic fluence modulation using multiple aperture devices.Journal of medical imaging (Bellingham, Wash.) · 2019Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
8 authors at 2 institutions in 2 countries.
Funding
Abstract
A novel beam filter consisting of multiple aperture devices (MADs) has been developed for dynamic fluence field modulation (FFM) in CT. Each MAD achieves spatial modulation of x-ray through fine-scale, highly attenuating tungsten bars of varying widths and spacings. Moiré patterns produced by relative motions between two MADs provide versatile classes of modulation profiles. The dual-MAD filter can be designed to achieve specific classes of target profiles. The designed filter was manufactured through a laser-sintering process and integrated to an experimental imaging system that enables linear actuation of the MADs. Dynamic FFM was achieved through a combination of beam shape modulation (by relative MAD motion) and amplitude modulation (by view-dependent mAs). To correct for gains associated with the MADs, we developed an algorithm to account for possible focal spot changes during/between scans and spectral effects introduced by the MADs. We performed FFM designs for phantoms following two imaging objectives: (1) to achieve minimum mean variance in filtered backprojection (FBP) reconstruction, and (2) to flatten the fluence behind the phantom. Comparisons with conventional FFM strategies involving a static bowtie and pulse width modulation were performed. The dual-MAD filter produced modulation profiles closely matched with the design target, providing varying beam widths not achievable by the static bowtie. The entire range of modulation profiles was achieved by 0.373 mm of MAD displacement. The correction algorithm effectively alleviated ring artifacts as a result of MADs while preserving phantom details such as wires and tissue boundaries. Dynamic FFM enabled by the MADs were effective in achieving the imaging objectives and demonstrated superior FFM capabilities compared to the static bowtie. In an ellipse phantom, the FFM of objective 1 achieved the lowest mean variance in all cases investigated. The FFM of objective 2 produce nearly isotropic local noise power spectrum and homogeneous noise magnitude. The dual-MAD filter provides an effective tool for fluence control in CT to overcome limitations of conventional static bowties and to further enable patient-specific FFM studies for a wide range of dose and image quality objectives.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.