Evidence map›Paper›PMID 30935342›Full record

ArticleThe Journal of manual & manipulative therapy2019

The C0-C2 axial rotation test: normal values, intra- and inter-rater reliability and correlation with the flexion rotation test in normal subjects.

Kiran Satpute, Sadaf Nalband, Toby Hall

Registry-linked trialAbstract readValidation Study
In one paragraph

Article in The Journal of manual & manipulative therapy, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT06689371 (Dry Needling Versus Dry Cupping on Pain and Disability in Cervicogenic Headache Patients), which is not on this map. Cited by 12 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
12citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

NCT06689371 nanot yet recruitingnot on this mapstarted 2024, after this paper: background citation

Dry Needling Versus Dry Cupping on Pain and Disability in Cervicogenic Headache Patients

TypeinterventionalSponsorCairo UniversityRan2024 to 2025Enrolled45ConditionsDry Needling, Dry Cupping, Cervicogenic HeadacheArmsGroup A (Dry Needling), Group B (Dry cupping), Group C (control)
3 · Its place in the literature

Who cites it

12 citing papers in PubMed, 1 synthesis or guideline pooled it.

  1. Pooled it
  2. Trial
  3. Trial
  4. Trial
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
  10. Article
  11. Article
  12. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Kiran Satputea Department of Kinesiotherapy and Physical Diagnosis, Department of Musculoskeletal Physiotherapy , Smt. Kashibai Navale College of Physiotherapy , Pune , India.
Sadaf Nalbandb Smt. Kashibai Navale College of Physiotherapy , Pune , India.
Toby Hallc School of Physiotherapy and Exercise Science , Curtin University , Perth , Australia.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectivesImpairment in upper cervical spine mobility is associated with cervicogenic headache severity and disability. Measures of such mobility include the flexion-rotation test (FRT), which requires full cervical flexion and may be influenced by lower cervical spine dysfunction. The C0-C2 axial rotation test also evaluates upper cervical mobility but normal values and reliability have not been reported. Our objective is to determine normal values, and intra-rater and inter-rater reliability of the C0-C2 axial rotation test.

methodsTwo therapists independently evaluated the FRT and C0-C2 axial rotation test with an iPhone compass application on 32 asymptomatic subjects with mean age 40.53 (SD 11.64) years on two occasions. Measurement procedures were standardized; and order of testing randomized.

resultsFor the FRT and C0-C2 axial rotation test reliability was high (ICC > 0.88). For rater one, Mean range to the left during the FRT and C0-C2 axial rotation test was 45.0° (6.04) and 14.43° (2.94), respectively, while range to the right was 44.6° (6.57) and 15.44° (2.68). For the FRT and C0-C2 axial rotation test the standard error of measurement was at most 2°, while the minimum detectable change was at most 4°. A strong positive correlation exists between the FRT and C0-C2 axial rotation test (r = 0.84, P < 0.01). DISCUSSION: The range recorded during the C0-C2 axial rotation test and FRT have high levels of reliability when evaluated using an iPhone. The strong correlation between the FRT and C0-C2 axial rotation test indicate that both may be measuring similar constructs, but each test needs to be referenced to normal values.

Indexed as

AdultAxis, Cervical VertebraBiomechanical PhenomenaCervical VertebraeFemaleHumansMaleObserver VariationPhysical ExaminationRange of Motion, ArticularReference ValuesReproducibility of ResultsRotationSpinal Diseasesflexion-rotation testgoniometerUpper cervical spine rotation

Identifiers

PMID30935342
PMCPMC6484503

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.