Evidence map›Paper›PMID 30934647›Full record

ArticleInternational journal of environmental research and public health2019

Statistical Evaluation of Radiofrequency Exposure during Magnetic Resonant Imaging: Application of Whole-Body Individual Human Model and Body Motion in the Coil.

Wenli Liu, Hongkai Wang, Pu Zhang, Chengwei Li, Jie Sun, Zhaofeng Chen, Shengkui Xing, Ping Liang, Tongning Wu

Open access · goldAbstract read
In one paragraph

Article in International journal of environmental research and public health, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
0.7field-weighted citation impact, top 33% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 11 citations in OpenAlex.

  1. Review
  2. Proposed Safety Guidelines for Patient Assistants in an Open MRI Environment.International journal of environmental research and public health · 2022
    Article
  3. Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors at 3 institutions in 1 country.

Wenli LiuDivision of Medical and Biological Measurement, National Institute of Metrology, Beijing 100029, China. liuwl@nim.ac.cn.
Hongkai WangSchool of Biomedical Engineering, Dalian University of Technology, Dalian 116024, China. wang.hongkai@dlut.edu.cn.ORCID 0000-0002-1813-2162
Pu ZhangDivision of Medical and Biological Measurement, National Institute of Metrology, Beijing 100029, China. zhangpu@nim.ac.cn.
Chengwei LiDivision of Medical and Biological Measurement, National Institute of Metrology, Beijing 100029, China. lichw@nim.ac.cn.
Jie SunDivision of Medical and Biological Measurement, National Institute of Metrology, Beijing 100029, China. sunj@nim.ac.cn.
Zhaofeng ChenSchool of Biomedical Engineering, Dalian University of Technology, Dalian 116024, China. zhaofeng.chen@foxmail.com.ORCID 0000-0003-3492-6656
Shengkui XingChina Academy of Information and Communications Technology, Beijing 100191, China. xingshengkui@163.com.
Ping LiangXGY Medical Equipment Co. Ltd., Ningbo 315400, China. clarke_ic@163.com.
Tongning WuChina Academy of Information and Communications Technology, Beijing 100191, China. wutongning@caict.ac.cn.ORCID 0000-0002-9894-9518
National Institute of Metrology · CNChina Academy of Information and Communications Technology · CNDalian University of Technology · CN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The accurate estimation of patient's exposure to the radiofrequency (RF) electromagnetic field of magnetic resonance imaging (MRI) significantly depends on a precise individual anatomical model. In the study, we investigated the applicability of an efficient whole-body individual modelling method for the assessment of MRI RF exposure. The individual modelling method included a deformable human model and tissue simplification techniques. Besides its remarkable efficiency, this approach utilized only a low specific absorption rate (SAR) sequence or even no MRI scan to generate the whole-body individual model. Therefore, it substantially reduced the risk of RF exposure. The dosimetric difference of the individual modelling method was evaluated using the manually segmented human models. In addition, stochastic dosimetry using a surrogate model by polynomial chaos presented SAR variability due to body misalignment and tilt in the coil, which were frequently occurred in the practical scan. In conclusion, the dosimetric equivalence of the individual models was validated by both deterministic and stochastic dosimetry. The proposed individual modelling method allowed the physicians to quantify the patient-specific SAR while the statistical results enabled them to comprehensively weigh over the exposure risk and get the benefit of imaging enhancement by using the high-intensity scanners or the high-SAR sequences.

Indexed as

Electromagnetic FieldsMagnetic Resonance ImagingFemaleHumansMaleModels, TheoreticalRadiation ExposureRadiometryRadio Wavesdeformable human modelnumerical simulationspecific absorption ratestochastic dosimetrytransmit coil

Identifiers

PMID30934647
PMCPMC6466328
OpenAlexW2924551035

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.