Evidence map›Paper›PMID 30931603›Full record

SynthesisJournal of diabetes science and technology2020

Tissue Response to Subcutaneous Infusion Catheter.

Ershuai Zhang, Zhiqiang Cao

Open access · bronzeAbstract readSystematic Review
In one paragraph

Synthesis in Journal of diabetes science and technology, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed
1.4field-weighted citation impact, top 18% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed, 23 citations in OpenAlex.

  1. Article
  2. Article
  3. Recent advances in oral insulin delivery technologies.Journal of controlled release : official journal of the Controlled Release Society · 2024
    Article
  4. Biomimetic polymers with phosphorylcholine groups as biomaterials for medical devices.Proceedings of the Japan Academy. Series B, Physical and biological sciences · 2024
    Review
  5. Article
  6. Review
  7. Article
  8. Leveraging Mechanical Forces to Target Insulin Injection-Induced Lipohypertrophy and Fibrosis.Diabetes spectrum : a publication of the American Diabetes Association · 2021
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

2 authors at 1 institution in 1 country.

Ershuai ZhangDepartment of Chemical Engineering and Materials Science, Wayne State University, Detroit, MI, USA.
Zhiqiang CaoDepartment of Chemical Engineering and Materials Science, Wayne State University, Detroit, MI, USA.
Wayne State University · US

Funding

A Novel Formulation Enabling Longevity of Subcutaneous Insulin InfusionDP2DK111910 · NIDDK · WAYNE STATE UNIVERSITY · PI CAO, ZHIQIANG · 2016 to 2016
$1.3M
NIDDK NIH HHS DP2 DK111910
6 · The paper itself

Abstract

Insulin infusion pump, continuous glucose monitoring (CGM), and insulin infusion set (IIS) have been developed to be increasingly feasible for people with type 1 diabetes (T1D). Several recently approved CGMs are transitioning from 7-day to 10-day wear time without the need for fingerprick recalibration. Nevertheless, studies and improvements on IIS, a critical part of insulin pump therapy, have been limited. In particular, the recommended wear time of IIS is still 2-3 days, which can hardly match the current duration of CGM for potential closed-loop system development. It is generally believed that both the inserted catheter and the subsequent infused insulin drug could induce particular subcutaneous tissue response and skin-related complications at the infusion site. In certain cases, poor glycaemic control, increased risk of hypoglycemia, and serious cosmetic impact on people with diabetes were observed. Skin complication has also been attributed as an important factor resulting users to discontinue insulin pump therapy. This article provides the rare systematic review of IIS induced subcutaneous tissue responses and skin complications, including the impacts from the inserted catheters, the subcutaneous infused insulin, and the adhesive or tape used to immobilize the catheter. The FDA's recommendation for the frequency of IIS change was further discussed. Future studies on this topic are required to further understand the IIS-related problems, and future strategies could be developed accordingly to significantly reduce the incidence of these problems, extend the wear time, and increase the acceptance of insulin pump based therapy.

Indexed as

CathetersForeign-Body ReactionInjection Site ReactionBlood GlucoseBlood Glucose Self-MonitoringDiabetes Mellitus, Type 1HumansInfusions, SubcutaneousInsulin Infusion SystemsSubcutaneous TissueBlood Glucosecontinuous subcutaneous insulin infusioninfusion catheterinsulin infusion setskin complicationstissue responsetype 1 diabetes

Identifiers

PMID30931603
PMCPMC7196874
OpenAlexW2928844361

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.