Evidence map›Paper›PMID 30931173›Full record

ArticleNature biomedical engineering2018

Reduction of measurement noise in a continuous glucose monitor by coating the sensor with a zwitterionic polymer.

Xi Xie, Joshua C Doloff, Volkan Yesilyurt, Atieh Sadraei, James J McGarrigle, Mustafa Omami, Omid Veiseh, Shady Farah, Douglas Isa, Sofia Ghani and 13 more

Open access · greenAbstract read
In one paragraph

Article in Nature biomedical engineering, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 69 papers, 2 of them syntheses that pooled it.

0numbers the graph read from it
0cells of the map it votes in
69citing papers in PubMed, 2 pooled it
10.0field-weighted citation impact, top 1% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

69 citing papers in PubMed, 2 syntheses or guidelines pooled it, 218 citations in OpenAlex.

  1. Pooled it
  2. Tissue Response to Subcutaneous Infusion Catheter.Journal of diabetes science and technology · 2020
    Pooled it
  3. Review
  4. Article
  5. Article
  6. Tissue-bioelectronics interfaces.Chemical Society reviews · 2026
    Review
  7. Article
  8. Article
  9. Article
  10. Article
  11. Article
  12. Review
  13. Review
  14. Article
  15. Review
  16. Article
  17. Article
  18. Article
  19. Article
  20. Article

9 more citing papers are in PubMed but not listed here.

4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

23 authors at 5 institutions in 2 countries.

Xi XieDavid H. Koch Institute for Integrative Cancer Research, Massachusetts Institute of Technology, Cambridge, MA, USA.ORCID http://orcid.org/0000-0001-7406-8444
Joshua C DoloffDavid H. Koch Institute for Integrative Cancer Research, Massachusetts Institute of Technology, Cambridge, MA, USA.
Volkan YesilyurtDavid H. Koch Institute for Integrative Cancer Research, Massachusetts Institute of Technology, Cambridge, MA, USA.
Atieh SadraeiDavid H. Koch Institute for Integrative Cancer Research, Massachusetts Institute of Technology, Cambridge, MA, USA.ORCID http://orcid.org/0000-0001-6180-0659
James J McGarrigleDivision of Transplantation, Department of Surgery, University of Illinois at Chicago, Chicago, IL, USA.
Mustafa OmamiDivision of Transplantation, Department of Surgery, University of Illinois at Chicago, Chicago, IL, USA.
Omid VeisehDavid H. Koch Institute for Integrative Cancer Research, Massachusetts Institute of Technology, Cambridge, MA, USA.ORCID http://orcid.org/0000-0003-1153-8079
Shady FarahDavid H. Koch Institute for Integrative Cancer Research, Massachusetts Institute of Technology, Cambridge, MA, USA.
Douglas IsaDivision of Transplantation, Department of Surgery, University of Illinois at Chicago, Chicago, IL, USA.
Sofia GhaniDivision of Transplantation, Department of Surgery, University of Illinois at Chicago, Chicago, IL, USA.
Ira JoshiDivision of Transplantation, Department of Surgery, University of Illinois at Chicago, Chicago, IL, USA.
Arturo VegasDavid H. Koch Institute for Integrative Cancer Research, Massachusetts Institute of Technology, Cambridge, MA, USA.
Jie LiDavid H. Koch Institute for Integrative Cancer Research, Massachusetts Institute of Technology, Cambridge, MA, USA.
Weiheng WangDavid H. Koch Institute for Integrative Cancer Research, Massachusetts Institute of Technology, Cambridge, MA, USA.
Andrew BaderDavid H. Koch Institute for Integrative Cancer Research, Massachusetts Institute of Technology, Cambridge, MA, USA.
Hok Hei TamDavid H. Koch Institute for Integrative Cancer Research, Massachusetts Institute of Technology, Cambridge, MA, USA.
Jun TaoState Key Laboratory of Optoelectronic Materials and Technologies, School of Electronics and Information Technology, Department of Hypertension and Vascular Disease, The First Affiliated Hospital, Sun Yat-Sen University, Guangzhou, China.
Hui-Jiuan ChenState Key Laboratory of Optoelectronic Materials and Technologies, School of Electronics and Information Technology, Department of Hypertension and Vascular Disease, The First Affiliated Hospital, Sun Yat-Sen University, Guangzhou, China.
Boru YangState Key Laboratory of Optoelectronic Materials and Technologies, School of Electronics and Information Technology, Department of Hypertension and Vascular Disease, The First Affiliated Hospital, Sun Yat-Sen University, Guangzhou, China.
Katrina Ann WilliamsonDavid H. Koch Institute for Integrative Cancer Research, Massachusetts Institute of Technology, Cambridge, MA, USA.
Jose OberholzerDivision of Transplantation, Department of Surgery, University of Illinois at Chicago, Chicago, IL, USA.
Robert LangerDavid H. Koch Institute for Integrative Cancer Research, Massachusetts Institute of Technology, Cambridge, MA, USA.
Daniel G AndersonDavid H. Koch Institute for Integrative Cancer Research, Massachusetts Institute of Technology, Cambridge, MA, USA. dgander@mit.edu.
Boston Children's Hospital · USUniversity of Illinois Chicago · USSun Yat-sen University · CNMassachusetts Institute of Technology · USHarvard University · US

Funding

The Development of Clinical Grade, Targeted Magnetic NanoparticlesU54CA151884 · NCI · MASSACHUSETTS INSTITUTE OF TECHNOLOGY · PI WEISSLEDER, MD, PHD, RALPH · 2010 to 2014
$11.3M
PHOTOPOLYMERIZATION FOR NONINVASIVE CARTILAGE TISSUER01DE013023 · NIDCR · MASSACHUSETTS INSTITUTE OF TECHNOLOGY · PI LANGER, ROBERT SAMUEL · 1998 to 2019
$6.8M
CONTROLLED RELEASE OF MACROMOLECULESR01EB000244 · NIBIB · MASSACHUSETTS INSTITUTE OF TECHNOLOGY · PI LANGER, ROBERT SAMUEL, TRAVERSO, CARLO GIOVANNI · 2002 to 2021
$6.1M
Controlled Release of MacromoleculesR37EB000244 · NIBIB · MASSACHUSETTS INSTITUTE OF TECHNOLOGY · PI LANGER, ROBERT SAMUEL · 2008 to 2017
$3.9M
Ultrasound Polymeric Drug DeliveryR01EB000351 · NIBIB · MASSACHUSETTS INSTITUTE OF TECHNOLOGY · PI LANGER, ROBERT SAMUEL · 2002 to 2013
$3.0M
Beta Cell Specific Microfluidic Perifusion and Imaging for Islet Potency TestingR01DK091526 · NIDDK · UNIVERSITY OF ILLINOIS AT CHICAGO · PI OBERHOLZER, JOSE · 2011 to 2015
$1.7M
NCI NIH HHS U54 CA151884NIBIB NIH HHS R01 EB000244NIBIB NIH HHS R01 EB000351NIBIB NIH HHS R37 EB000244NIDCR NIH HHS R01 DE013023NIDDK NIH HHS R01 DK091526
6 · The paper itself

Abstract

Continuous glucose monitors (CGMs), used by patients with diabetes mellitus, can autonomously track fluctuations in blood glucose over time. However, the signal produced by CGMs during the initial recording period following sensor implantation contains substantial noise, requiring frequent recalibration via fingerprick tests. Here, we show that coating the sensor with a zwitterionic polymer, found via a combinatorial-chemistry approach, significantly reduces signal noise and improves CGM performance. We evaluated the polymer-coated sensors in mice as well as in healthy and diabetic non-human primates, and show that the sensors accurately record glucose levels without the need for recalibration. We also show that the polymer-coated sensors significantly abrogated immune responses to the sensor, as indicated by histology, fluorescent whole-body imaging of inflammation-associated protease activity, and gene expression of inflammation markers. The polymer coating may allow CGMs to become standalone measuring devices.

Indexed as

AnimalsBiosensing TechniquesBlood GlucoseCoated Materials, BiocompatibleDiabetes Mellitus, ExperimentalElectrochemical TechniquesElectrodesFemaleHumansMaleMiceMice, Inbred C57BLPolymersReactive Oxygen SpeciesSignal-To-Noise RatioSkinBlood GlucoseCoated Materials, BiocompatiblePolymersReactive Oxygen Species

Identifiers

PMID30931173
PMCPMC6436621
OpenAlexW2884370030

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.