Evidence map›Paper›PMID 30929023›Full record

ArticleJournal of radiation research2019

Patient organ doses from megavoltage computed tomography delivery with a helical tomotherapy unit using a general treatment planning system.

Hironori Nagata, Satoru Sugimoto, Hideyuki Hongo, Harumitsu Hashimoto, Yuki Sato, Toru Kawabata, Hiroyuki Watanabe, Tatsuya Inoue, Keisuke Usui, Chie Kurokawa and 1 more

Abstract read
In one paragraph

Article in Journal of radiation research, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

11 authors.

Hironori NagataDepartment of Radiation Oncology, Graduate School of Medicine, Juntendo University, Bunkyo-ku, Tokyo, Japan.
Satoru SugimotoDepartment of Radiation Oncology, Graduate School of Medicine, Juntendo University, Bunkyo-ku, Tokyo, Japan.
Hideyuki HongoDepartment of Radiation Oncology, Shonan Kamakura General Hospital, Kamakura, Kanagawa, Japan.
Harumitsu HashimotoDepartment of Radiology, Shonan Fujisawa Tokusyukai Hospital, Fujisawa, Kanagawa, Japan.
Yuki SatoTechnical Support Group, Radiation Therapy Technical Support Department, Hitachi, Ltd Healthcare Business Unit, Taito-ku, Tokyo, Japan.
Toru KawabataDepartment of Radiation Oncology, Graduate School of Medicine, Juntendo University, Bunkyo-ku, Tokyo, Japan.
Hiroyuki WatanabeDepartment of Radiation Oncology, Graduate School of Medicine, Juntendo University, Bunkyo-ku, Tokyo, Japan.
Tatsuya InoueDepartment of Radiology, Juntendo University Urayasu Hospital, Urayasu, Chiba, Japan.
Keisuke UsuiDepartment of Radiation Oncology, Graduate School of Medicine, Juntendo University, Bunkyo-ku, Tokyo, Japan.
Chie KurokawaDepartment of Radiation Oncology, Graduate School of Medicine, Juntendo University, Bunkyo-ku, Tokyo, Japan.
Keisuke SasaiDepartment of Radiation Oncology, Graduate School of Medicine, Juntendo University, Bunkyo-ku, Tokyo, Japan.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The purpose of this study was to quantify actual patient organ doses from megavoltage computed tomography (MVCT) using an MVCT beam model of a helical tomotherapy unit in a general treatment planning system (TPS). Dosimetric parameters (percentage depth dose, lateral beam profile, and longitudinal beam profile) of the MVCT beam were measured using Gafchromic EBT3 films (ISP Corporation, Wayne, NJ, USA) and used for beam modeling in a Pinnacle3 TPS (Philips, Amsterdam, Netherlands); this TPS is widely used with linear accelerators. The created beam model was adjusted and validated by assessing point doses in a cylindrical phantom in static and helical beam plans with fine, normal and coarse pitches. Maximum doses delivered to important organs from MVCT delivery for five clinical cases were calculated using the created beam model. The difference (average ± one standard deviation for all evaluation points) between calculated and measured doses was -0.69 ± 1.20% in the static beam plan. In the helical beam plan, the differences were 1.83 ± 2.65%, 1.35 ± 5.94% and -0.66 ± 8.48% for fine, normal and coarse pitches, respectively. The average maximum additional dose to important organs from MVCT in clinical cases was 0.82% of the prescribed dose. In conclusion, we investigated a method for quantifying patient organ dose from MVCT delivery on helical tomotherapy using an MVCT beam model in a general TPS. This technique enables estimation of the patient-specific organ dose from MVCT delivery, without the need for additional equipment.

Indexed as

Radiotherapy Planning, Computer-AssistedTomography, Spiral ComputedCalibrationDose-Response Relationship, RadiationHumansOrgan SpecificityRadiotherapy DosageReproducibility of ResultsTomography, X-Ray Computedgeneral treatment planning systemhelical tomotherapyMVCTpatient-specific organ dose

Identifiers

PMID30929023
PMCPMC6530616

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.