ArticleSensors (Basel, Switzerland)2019
Design of a Wearable 12-Lead Noncontact Electrocardiogram Monitoring System.
Article in Sensors (Basel, Switzerland), 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 12 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
12 citing papers in PubMed.
- Applications of Smart Textiles for Ambulatory Electrocardiogram Monitoring: Scoping Review of the Literature.JMIR cardio · 2026Article
- A New Self-Made 16-Channel Capacitive Electrocardiography System: An Investigation and Validation for Non-Contact Electrodes.Sensors (Basel, Switzerland) · 2025Article
- Ultrasoft Long-Lasting Reusable Hydrogel-Based Sensor Patch for Biosignal Recording.Biosensors · 2024Article
- Feasibility of patch-type wireless 12-lead electrocardiogram in laypersons.Scientific reports · 2023Article
- Development of wearable multi-lead ECG measurement device using cubic flocked electrode.Scientific reports · 2022Article
- Robustness of electrocardiogram signal quality indices.Journal of the Royal Society, Interface · 2022Review
- An Overview of Sensors, Design and Healthcare Challenges in Smart Homes: Future Design Questions.Healthcare (Basel, Switzerland) · 2021Review
- An Automated High-Accuracy Detection Scheme for Myocardial Ischemia Based on Multi-Lead Long-Interval ECG and Choi-Williams Time-Frequency Analysis Incorporating a Multi-Class SVM Classifier.Sensors (Basel, Switzerland) · 2021Article
- Common-Mode Noise Reduction in Noncontact Biopotential Acquisition Circuit Based on Imbalance Cancellation of Electrode-Body Impedance.Sensors (Basel, Switzerland) · 2020Article
- Human Vital Signs Detection Methods and Potential Using Radars: A Review.Sensors (Basel, Switzerland) · 2020Review
- Data Analytics and Applications of the Wearable Sensors in Healthcare: An Overview.Sensors (Basel, Switzerland) · 2020Article
- Wearable Vital Signs Monitoring for Patients With Asthma: A Review.IEEE sensors journal · 2020Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
A standard 12-lead electrocardiogram (ECG) is an important tool in the diagnosis of heart diseases. Here, Ag/AgCl electrodes with conductive gels are usually used in a 12-lead ECG system to access biopotentials. However, using Ag/AgCl electrodes with conductive gels might be inconvenient in a prehospital setting. In previous studies, several dry electrodes have been developed to improve this issue. However, these dry electrodes have contact with the skin directly, and they might be still unsuitable for patients with wounds. In this study, a wearable 12-lead electrocardiogram monitoring system was proposed to improve the above issue. Here, novel noncontact electrodes were also designed to access biopotentials without contact with the skin directly. Moreover, by using the mechanical design, this system allows the user to easily wear and take off the device and to adjust the locations of the noncontact electrodes. The experimental results showed that the proposed system could exactly provide a good ECG signal quality even while walking and could detect the ECG features of the patients with myocardial ischemia, installation pacemaker, and ventricular premature contraction.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.