Evidence map›Paper›PMID 30921342›Full record

ArticlePloS one2019

Live video rate volumetric OCT imaging of the retina with multi-MHz A-scan rates.

Jan Philip Kolb, Wolfgang Draxinger, Julian Klee, Tom Pfeiffer, Matthias Eibl, Thomas Klein, Wolfgang Wieser, Robert Huber

Erratum issuedAbstract read
In one paragraph

Article in PloS one, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. An erratum has been issued. Cited by 34 papers.

0numbers the graph read from it
0cells of the map it votes in
34citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

34 citing papers in PubMed.

  1. Article
  2. Article
  3. New Directions for Ophthalmic OCT - Handhelds, Surgery, and Robotics.Translational vision science & technology · 2025
    Review
  4. Article
  5. Article
  6. Quantitative Optical Coherence Elastography of the Optic Nerve Head In Vivo.IEEE transactions on bio-medical engineering · 2024
    Article
  7. Article
  8. Article
  9. Article
  10. Article
  11. Article
  12. Article
  13. Article
  14. Article
  15. Article
  16. Article
  17. Fourier Domain Mode Locked Laser and Its Applications.Sensors (Basel, Switzerland) · 2022
    Review
  18. Article
  19. Article
  20. Continuous spectral zooming forBiomedical optics express · 2022
    Article
4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

8 authors.

Jan Philip KolbInstitut für Biomedizinische Optik, Universität zu Lübeck, Lübeck, Germany.
Wolfgang DraxingerInstitut für Biomedizinische Optik, Universität zu Lübeck, Lübeck, Germany.
Julian KleeInstitut für Biomedizinische Optik, Universität zu Lübeck, Lübeck, Germany.
Tom PfeifferInstitut für Biomedizinische Optik, Universität zu Lübeck, Lübeck, Germany.
Matthias EiblInstitut für Biomedizinische Optik, Universität zu Lübeck, Lübeck, Germany.
Thomas KleinOptores GmbH, München, Germany.
Wolfgang WieserOptores GmbH, München, Germany.
Robert HuberInstitut für Biomedizinische Optik, Universität zu Lübeck, Lübeck, Germany.ORCID 0000-0001-9785-6574

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Surgical microscopes are vital tools for ophthalmic surgeons. The recent development of an integrated OCT system for the first time allows to look at tissue features below the surface. Hence, these systems can drastically improve the quality and reduce the risk of surgical interventions. However, current commercial OCT-enhanced ophthalmic surgical microscopes provide only one additional cross sectional view to the standard microscope image and feature a low update rate. To present volumetric data at a high update rate, much faster OCT systems than the ones applied in today's surgical microscopes need to be developed. We demonstrate live volumetric retinal OCT imaging, which may provide a sufficiently large volume size (330x330x595 Voxel) and high update frequency (24.2 Hz) such that the surgeon may even purely rely on the OCT for certain surgical maneuvers. It represents a major technological step towards the possible application of OCT-only surgical microscopes in the future which would be much more compact thus enabling many additional minimal invasive applications. We show that multi-MHz A-scan rates are essential for such a device. Additionally, advanced phase-based OCT techniques require 3D OCT volumes to be detected with a stable optical phase. These techniques can provide additional functional information of the retina. Up to now, classical OCT was to slow for this, so our system can pave the way to holographic OCT with a traditional confocal flying spot approach. For the first time, we present point scanning volumetric OCT imaging of the posterior eye with up to 191.2 Hz volume rate. We show that this volume rate is high enough to enable a sufficiently stable optical phase to a level, where remaining phase errors can be corrected. Applying advanced post processing concepts for numerical refocusing or computational adaptive optics should be possible in future with such a system.

Indexed as

Cross-Sectional StudiesHumansImage Interpretation, Computer-AssistedMicroscopyRetinaTomography, Optical CoherenceVideo Recording

Identifiers

PMID30921342
PMCPMC6438632

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.